50133020 | MSI-SR-LC21DT30-01 - Safety relay
Описание
Информация для заказа
Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | MSI-SR-LC21DT | ||||||
Application | Base device for E-Stop and safety door applications | ||||||
Functions | |||||||
Functions | Monitoring of proximity switches, Monitoring of E-Stop circuits, Monitoring of optoelectronic protective devices, Monitoring of position switches | ||||||
Restart | Automatic, Manual | ||||||
Characteristic parameters | |||||||
SIL | 3, IEC 61508 | ||||||
SILCL | 3, IEC/EN 62061 | ||||||
Performance Level (PL) | e, EN ISO 13849-1 | ||||||
PFHD | 3E-08 per hour | ||||||
Mission time | 20 years, EN ISO 13849-1 | ||||||
Category | 4, EN ISO 13849 | ||||||
Electrical data | |||||||
Supply circuit | |||||||
Nominal voltage UN | 24 V DC | ||||||
Min. rated control supply voltage US at DC | 20.4 V | ||||||
Max. rated control supply voltage at DC | 26.4 V | ||||||
Min. rated control supply voltage at DC | 20.4 V | ||||||
Rated power DC | 2.6 W | ||||||
Galvanic isolation between supply and control circuit | No | ||||||
Output circuit | |||||||
Number of outputs, safety-oriented, undelayed, contact-based | 2 Piece(s) | ||||||
Number of outputs, safety-oriented, delayed, contact-based | 1 Piece(s) | ||||||
Release current paths, time-delayed | NO contact, off-delay | ||||||
Contact material | Ag alloy, gold-plated | ||||||
Usage category AC-15 (NO contact) | Ue 230V, Ie 3A | ||||||
Usage category DC-13 (NO contact) | Ue 24V, Ie 2A | ||||||
Short circuit protection (NO contact) | gG class safety fuse 6A, melting integral | ||||||
Nominal switching voltage, release current paths AC | 230 V | ||||||
Max. thermal continuous current Ith, release current paths | 6 A | ||||||
Max. total current I² of all current paths | 5 A² | ||||||
Mechanical life time | 100,000,000 switching cycles | ||||||
Control circuit | |||||||
Evaluation of the inputs | Two-channel | ||||||
Nominal output voltage DC | 22 V | ||||||
Input current at the control inputs (safety circuit/reset circuit) | 25 mA | ||||||
Max. peak current at the control inputs (safety circuit/reset circuit) | 2,500 mA | ||||||
Max. cable resistance, per channel | ≤ (5 + (1.176 x UB / UN - 1) x 100) Ω | ||||||
Minimum switch-on time | 200 ms | ||||||
Response time (automatic start tA2) | 700 ms | ||||||
Response time (manual start tA1) | 30 ms | ||||||
Test pulse time permitted tTP | 1 ms | ||||||
Release time tR | 25 ms | ||||||
Release time tR, time-delayed contacts (tolerance) | 0.15 s ... 3 s ± 16 % | ||||||
Sychronous time monitoring tS | 500 ms | ||||||
Recovery time tW | 500 ms | ||||||
Connection | |||||||
Number of connections | 1 Piece(s) | ||||||
Connection 1 | |||||||
Type of connection | <td align="center" class="val" colspan="6</tr>
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
День | Время работы |
---|---|
Понедельник | 09:00-17:00 |
Вторник | 09:00-17:00 |
Среда | 09:00-17:00 |
Четверг | 09:00-17:00 |
Пятница | 09:00-17:00 |
Суббота | Выходной |
Воскресенье | Выходной |