549954 | MSI-MD-FBX - Muting interface
Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | MSI-MD-FB | ||||||
Functions | |||||||
Functions | Muting enable function, Muting-timeout extension, Timing controlled 2-sensor muting | ||||||
Restart | Automatic, Manual | ||||||
Characteristic parameters | |||||||
SIL | 3, IEC 61508 | ||||||
SILCL | 3, IEC/EN 62061 | ||||||
Performance Level (PL) | e, EN ISO 13849-1 | ||||||
PFHD | 2.5E-09 per hour | ||||||
Mission time | 20 years, EN ISO 13849-1 | ||||||
Category | 4, EN ISO 13849 | ||||||
Electrical data | |||||||
Protective circuit | Short circuit protected, Overvoltage protection, Polarity reversal protection | ||||||
Performance data | |||||||
Supply voltage UB | 24 V, DC, -20 ... 20 %, Compensation necessary at 20 ms voltage dip, min. 250 mA (+ external loads) | ||||||
Current consumption, max. | 150 mA, Without external load | ||||||
Residual ripple | -5 ... 5 %, From UB | ||||||
Protective circuit | Short circuit protected, Overvoltage protection, Polarity reversal protection | ||||||
Inputs | |||||||
Number of safety-related switching inputs | 2 Piece(s) | ||||||
Number of digital switching inputs | 8 Piece(s) | ||||||
Switching inputs | |||||||
Type | Digital switching input | ||||||
Switching voltage high, min. | 27 V | ||||||
Switching voltage low, max. | 2.5 V | ||||||
Switching voltage, typ. | 24 V | ||||||
Voltage type | DC | ||||||
Number of digital switching inputs | 8 Piece(s) | ||||||
Digital switching input 1 | |||||||
Function | Control input for Reset, Control input, reset of the control | ||||||
Number of digital switching inputs | 8 Piece(s) | ||||||
Digital switching input 2 | |||||||
Function | Control input, muting sensor 1 of the control | ||||||
Number of digital switching inputs | 8 Piece(s) | ||||||
Digital switching input 3 | |||||||
Function | Control input, muting enable/muting timeout | ||||||
Number of digital switching inputs | 8 Piece(s) | ||||||
Digital switching input 4 | |||||||
Function | Control input for Reset | ||||||
Number of digital switching inputs | 8 Piece(s) | ||||||
Digital switching input 5 | |||||||
Function | Control input for muting sensor 3, Control input for muting sensor 1, Control input for muting sensor 2, Control input for muting sensor 4 | ||||||
Number of digital switching inputs | 8 Piece(s) | ||||||
Safety-related switching inputs | |||||||
Type | Safety switching input | ||||||
Voltage type | DC | ||||||
Switching voltage high, min. | 27 V | ||||||
Switching voltage low, max. | 18 V | ||||||
Switching voltage, typ. |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком