547959 | MSI-TR1B-02 - Safety relay

Описание
Информация для заказа
Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | MSI-TB | ||||||
Functions | |||||||
Functions | Periodic function test, "Error" signal output, "Safety ON" signal output, Contactor monitoring (EDM), selectable, Start/restart interlock (RES), selectable | ||||||
Restart | Automatic, Manual | ||||||
Characteristic parameters | |||||||
Type | 2, IEC/EN 61496 | ||||||
Performance Level (PL) | Up to c, EN ISO 13849-1 | ||||||
MTTFd | 78 years, EN ISO 13849-1 | ||||||
PFHD | 8.8E-08 per hour | ||||||
Mission time | 20 years, EN ISO 13849-1 | ||||||
Category | 2, EN ISO 13849 | ||||||
Electrical data | |||||||
Protective circuit | Polarity reversal protection, Short circuit protected | ||||||
Performance data | |||||||
Supply voltage UB | 24 V, DC, -20 ... 20 % | ||||||
Current consumption, max. | 200 mA, Without external load | ||||||
Residual ripple | -15 ... 15 % | ||||||
Fuse | External with max. 3.15 A semi time-lag | ||||||
Protective circuit | Polarity reversal protection, Short circuit protected | ||||||
Inputs | |||||||
Number of digital switching inputs | 4 Piece(s) | ||||||
Switching inputs | |||||||
Type | Digital switching input | ||||||
Switching voltage high, min. | 18.2 V | ||||||
Switching voltage low, max. | 2.5 V | ||||||
Switching voltage, typ. | 23 V | ||||||
Voltage type | DC | ||||||
Number of digital switching inputs | 4 Piece(s) | ||||||
Digital switching input 1 | |||||||
Function | Control input for contactor monitoring (EDM) | ||||||
Number of digital switching inputs | 4 Piece(s) | ||||||
Digital switching input 2 | |||||||
Function | Control input for receiver | ||||||
Number of digital switching inputs | 4 Piece(s) | ||||||
Digital switching input 3 | |||||||
Function | RES/Start control input | ||||||
Number of digital switching inputs | 4 Piece(s) | ||||||
Digital switching input 4 | |||||||
Function | Control input for Reset | ||||||
Number of digital switching inputs | 4 Piece(s) | ||||||
Digital switching input 5 | |||||||
Function | Restart interlock control input | ||||||
Number of digital switching inputs | 4 Piece(s) | ||||||
Protective circuit | Polarity reversal protection, Short circuit protected | ||||||
Outputs | |||||||
Number of safety-related switching outputs (OSSDs) | 2 Piece(s) | ||||||
Number of digital switching outputs | 3 Piece(s) | ||||||
Safety-related switching outputs | |||||||
Type | Safety-related switching output OSSD < |
- Цена: Цену уточняйте
Информация для покупателя
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
День | Время работы |
---|---|
Понедельник | 09:00-17:00 |
Вторник | 09:00-17:00 |
Среда | 09:00-17:00 |
Четверг | 09:00-17:00 |
Пятница | 09:00-17:00 |
Суббота | Выходной |
Воскресенье | Выходной |