547953 | MSI-SR5B-02 - Safety relay

Basic data | |||||||
|---|---|---|---|---|---|---|---|
| Series | MSI-SR5B | ||||||
Functions | |||||||
| Functions | Double sensor monitoring, Automatic start/restart, Contactor monitoring (EDM), Cross circuit monitoring, Start/restart interlock (RES), selectable | ||||||
| Restart | Automatic, Manual | ||||||
Characteristic parameters | |||||||
| SIL | 3, IEC 61508 | ||||||
| SILCL | 3, IEC/EN 62061 | ||||||
| Performance Level (PL) | e, EN ISO 13849-1 | ||||||
| MTTFd | 73 years, EN ISO 13849-1 | ||||||
| PFHD | 1E-08 per hour | ||||||
| PFHD, nop = 4800 | 0.00000001 per hour | ||||||
| PFHD, nop = 28800 | 0.00000002 per hour | ||||||
| PFHD, nop = 86400 | 0.00000005 per hour | ||||||
| Mission time | 20 years, EN ISO 13849-1 | ||||||
| Category | 4, EN ISO 13849 | ||||||
| STOP category | 0, IEC/EN 60204-1 | ||||||
| B10d at AC1 (ohmic load) | 400,000 number of cycles | ||||||
| B10d at DC13 (inductive load) | 4,000,000 number of cycles | ||||||
Electrical data | |||||||
| Protective circuit | Fuse on switching output, upstream | ||||||
| Switching frequency, max. | 3600 switching cycles/h | ||||||
| Continuous current per current path, max. | 2 A | ||||||
| Input current, max. | 150 mA | ||||||
| External safeguarding for supply circuit | 200 mA delay-action | ||||||
| External contact fuse protection per current path | 5 A quick-action, or 3.15 A delay-action | ||||||
| Permissible input line resistance, max. | 30 Ω | ||||||
Performance data | |||||||
| Supply voltage UB | 24 V, DC, -20 ... 20 % | ||||||
| Current consumption, max. | Without external load | ||||||
| Permissible input line resistance, max. | 30 Ω | ||||||
Outputs | |||||||
| Number of safety-related switching outputs (OSSDs) | 2 Piece(s) | ||||||
Safety-related switching outputs | |||||||
| Type | Safety-related switching output OSSD | ||||||
| Voltage type | DC | ||||||
| Number of safety-related switching outputs (OSSDs) | 2 Piece(s) | ||||||
Safety-related switching output 1 | |||||||
| Switching element | Relay, NO | ||||||
| Number of safety-related switching outputs (OSSDs) | 2 Piece(s) | ||||||
Safety-related switching output 2 | |||||||
| Switching element | Relay, NO | ||||||
| Number of safety-related switching outputs (OSSDs) | 2 Piece(s) | ||||||
| Permissible input line resistance, max. | 30 Ω | ||||||
Timing | |||||||
| Pickup delay, automatic start | 350 ms | ||||||
| Pickup delay, manual start | 50 ms | ||||||
| Regression delay | 10 ms | ||||||
| Test pulse acceptance, max. | 1 ms | ||||||
| Time window between 2 channels of a sensor, max. | 60 ms | ||||||
Connection | |||||||
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |


Basic data