547932 | MSI-TRMB-02 - Safety relay
Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | MSI-TRM | ||||||
Functions | |||||||
Functions | Start/restart interlock (RES) | ||||||
Restart | Automatic, Manual | ||||||
Characteristic parameters | |||||||
Type | 4, IEC/EN 61496 | ||||||
SIL | 3, IEC 61508 | ||||||
SILCL | 3, IEC/EN 62061 | ||||||
Performance Level (PL) | Up to and including e, EN ISO 13849-1 | ||||||
MTTFd | 100 years, EN ISO 13849-1 | ||||||
PFHD | 2.15E-09 per hour | ||||||
Mission time | 20 years, EN ISO 13849-1 | ||||||
Category | 4, EN ISO 13849 | ||||||
Electrical data | |||||||
Protective circuit | Short circuit protected, Polarity reversal protection | ||||||
Performance data | |||||||
Supply voltage UB | 24 V, DC, -20 ... 20 % | ||||||
Current consumption, max. | 200 mA | ||||||
Power consumption, max. | 3 W, For 24 V, plus output load | ||||||
Residual ripple | 0 ... 15 % | ||||||
Fuse | External with max. 3 A | ||||||
Protective circuit | Short circuit protected, Polarity reversal protection | ||||||
Inputs | |||||||
Number of safety-related switching inputs | 2 Piece(s) | ||||||
Number of digital switching inputs | 2 Piece(s) | ||||||
Switching inputs | |||||||
Type | Digital switching input | ||||||
Switching voltage high, min. | 18.2 V | ||||||
Switching voltage low, max. | 2.5 V | ||||||
Switching voltage, typ. | 23 V | ||||||
Voltage type | DC | ||||||
Number of digital switching inputs | 2 Piece(s) | ||||||
Digital switching input 1 | |||||||
Function | Control input for start/restart interlock (RES) | ||||||
Number of digital switching inputs | 2 Piece(s) | ||||||
Digital switching input 2 | |||||||
Function | Control input for start/restart interlock (RES) | ||||||
Number of digital switching inputs | 2 Piece(s) | ||||||
Safety-related switching inputs | |||||||
Type | Safety switching input | ||||||
Voltage type | DC | ||||||
Switching voltage high, min. | 18.2 V | ||||||
Switching voltage low, max. | 2.5 V | ||||||
Switching voltage, typ. | 23 V | ||||||
Number of digital switching inputs | 2 Piece(s) | ||||||
Protective circuit | Short circuit protected, Polarity reversal protection | ||||||
Outputs | |||||||
Number of safety-related switching outputs (OSSDs) | 2 Piece(s) | ||||||
Number of digital switching outputs | 3 Piece(s) | ||||||
Safety-related switching outputs | |||||||
Type | Safety-related switching output OSSD | <
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
День | Время работы |
---|---|
Понедельник | 09:00-17:00 |
Вторник | 09:00-17:00 |
Среда | 09:00-17:00 |
Четверг | 09:00-17:00 |
Пятница | 09:00-17:00 |
Суббота | Выходной |
Воскресенье | Выходной |