VK-X1100

Описание
Информация для заказа
| Model | VK-X1100 | |||
| Type | Head unit | |||
| Total magnification | Up to 28,800 x*1 | |||
| Field of view (minimum range) | 11 µm to 7,398 µm | |||
| Frame rate (laser measurement speed) | 4 to 125 Hz, 7,900 Hz*2 | |||
| Measurement principle | Optical system | Pinhole confocal optical system, Focus variation | ||
| Light-receiving element | 16-bit photomultiplier: High-definition color CMOS | |||
| Scanning method (during general measurement and image stitching) | Automatic upper/lower limit setting, high-speed light intensity optimization (AAGII) , poor reflected light intensity supplement (Double Scan) | |||
| Height measurement | Display resolution | 0.5 nm | ||
| Linear scale | ||||
| Dynamic range | 16 bits | |||
| Repeatability σ | Laser confocal | 20 x: 40 nm, 50 x: 12 nm | ||
| Focus variation | 5 x: Или отправьте нам запрос на 50 nm, 50 x: 20 nm | |||
| Height data acquisition range | 700,000 steps | |||
| Accuracy | 0.2 + L /100 µm or less (L = Measuring length)*3 | |||
| Width measurement | Display resolution | 1 nm | ||
| Repeatability 3σ | Laser confocal | 20 x: 100 nm, 50 x: 50 nm | ||
| Focus variation | 5 x: Или отправьте нам запрос на 120 nm, 50 x: 50 nm | |||
| Accuracy | Measured value ±2 % or less*3 | |||
| XY stage configuration | Manual: Operating range | 70 mm x 70 mm 2.76" x 2.76" | ||
| Motorized: Operating range | 100 mm x 100 mm 3.94" x 3.94" | |||
| Observation | Observation image | High-resolution color CMOS image 16-bit laser color confocal image Confocal + ND filter optical system C-laser differential interference image | ||
| Lighting | Ring illumination, coaxial illumination | |||
| Measurement laser light source | Wavelength | Violet semiconductor laser, 404 nm | ||
| Maximum output | 1 mW | |||
| Laser class | Class 2 laser product (IEC60825-1, FDA (CDRH) Part 1040.10*4) | |||
| Power supply | Power voltage | 100 to 240 VAC, 50/60 Hz | ||
| Power consumption | 150 VA | |||
| Weight | Approx. 13.0 kg | |||
| *1 When using a 23 inch full-screen display. *2 At top speed when using a combination of measurement mode/measurement quality/lens magnification. When the line scan has a measurement pitch that is within 0.1 µm. *3 When measuring a standard sample (standard scale) with a 20 x or greater lens. *4 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No. 50. | ||||
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |
Или отправьте нам запрос на e-mail: zapros@filfar.by
- Цена: Цену уточняйте
Информация для покупателя
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |