Functional safety related parameters

Safety Integrity Level (SIL)SIL 3

Supply

ConnectionSL1: 1a, 1b(-); 2a, 2b(+)
Rated voltage20.4 ... 30 V DC via Termination Board
Rated current28 mA at 24 V , RS-485, quiescent current
Power dissipation0.7 W at 24 V

HART signal channels (non-intrinsically safe)

Number of channels32
ConformityHART field device input (revision 5 to 7)
Signal range0.12 Vpp < signal < 1.5 Vpp
Leakage current< 3 µA at -20 ... 85 °C (-4 ... 185 °F)
Terminating resistorexternal 230 ... 500 ? standard (up to 1000 ? possible)
Output voltage? 400 mV ss (with the terminator resistance specified above)
Output resistance100 ? or smaller, capacitive coupling
DC isolationdual capacitor each channel
Common mode voltageup to 30 V
Input impedance> 5 k? , according to HART specification
Input voltage range0.12 ... 1.5 V ss
Common mode voltagemax. 30 V
Differential mode clamping± 5.2 V , for transient or AC signals
Common mode clamping± 10 V , for transient or AC signals
Carrier detect levelsignal > 0.12 Vpp, carrier detection activated
signal < 0.08 Vpp, carrier detection not activated
Transmit amplitude200 ? load, 0.43 Vpp < signal < 0.49 Vpp
500 ? load, 1.1 Vpp < signal < 1.2 Vpp
Device typeDC isolated bus device
Impedancehigh impedance
Data link typeHART primary and secondary
Field multi point supportoption available upon request

Interface

Transfer rate9600 MBit/s, 19200 MBit/s or 38400 MBit/s, selectable via switch
Address1 ... 31 , adjustable via DIP switch
TypeRS-485 , differential pair and grounding
Topologymulti point, master/slave connection

Galvanic isolation

Interface/power supply500 Vrms
Interface/field channels1000 Veff
Power supply/field channels1000 Veff

Indicators/settings

Display elementsLEDs
LED PWR ON (power supply), one green LED
LED HART TX (HART transmission), one yellow LED
LED FAULT (lead fault), one red LED
Control elementsDIP switches at the housing side for:
- unit slave address
- baud rate
- test mode on/off
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility

Conformity

Electromagnetic compatibilityNE 21:2012
For further information see system description.
Degree of protectionIEC 60529:2001

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Relative humidity5 ... 95 %, noncondensing

Mechanical specifications

Degree of protectionIP20
Massapprox. 140 g
Dimensions18 x 106 x 128 mm (0.7 x 4.2 x 5 inch)
Mountingon Termination Board

Data for application in connection with hazardous areas

CertificateCML 17 ATEX 3337 X
Directive conformity

International approvals

CSA approval
IECEx approval

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 

8 (017) 255-8-000

Или отправьте нам запрос на e-mail:  zapros@filfar.by

 

Информация для заказа
  • Цена: Цену уточняйте
Контакты
  • Телефон:
    +375 (44) 765-55-50
    +375 (29) 690-11-55
  • Контактное лицо:
    Сергей, Владимир
  • Адрес:
    ул. Западная, д.13, каб.519, Минск, 220036, Беларусь
  • Email:
    zapros@filfar.by
Карта