Digital Input LB1008A

Slots | |
|---|---|
| Occupied slots | 2 |
Supply | |
| Connection | backplane bus |
| Rated voltage | 12 V DC , only in connection with the power supplies LB9*** |
| Power dissipation | 0.95 W |
| Power consumption | 0.95 W |
Internal bus | |
| Connection | backplane bus |
| Interface | manufacturer-specific bus to standard com unit |
Digital input | |
| Number of channels | 8 |
| Sensor interface | |
| Connection | channel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8-; channel V: 9+, 10-; channel VI: 11+, 12-; channel VII: 13+, 14-; channel VIII: 15+, 16- |
| Rated values | acc. to EN 60947-5-6 (NAMUR) |
| Digital signals (active) | Use in safe area: configurable 24 V 5 V |
| Switching point/switching hysteresis | 1.2 ... 2.1 mA / ± 0.2 mA |
| Voltage | 8.2 V |
| Internal resistor | 1 k? |
| Line fault detection | can be switched on/off for each channel via configuration tool , active signals (24 V, 5 V) without line fault detection |
| Minimum pulse duration | 1 ms |
Indicators/settings | |
| LED indication | Power LED (P) green: supply Status LED (I) red: line fault |
| Coding | optional mechanical coding via front socket |
Directive conformity | |
| Electromagnetic compatibility | |
Conformity | |
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Environmental test | EN 60068-2-14 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Damaging gas | EN 60068-2-42 |
| Relative humidity | EN 60068-2-56 |
Ambient conditions | |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications | |
| Degree of protection | IP20 when mounted on backplane |
| Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14...1.5mm2) or screw terminals (0.08...1.5mm2) |
| Mass | approx. 130 g |
| Dimensions | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
Data for application in connection with hazardous areas | |
| Certificate | PF 08 CERT 1234 X |
| Galvanic isolation | |
| Directive conformity | |
International approvals | |
| IECEx approval | BVS 09.0037X |
| Marin | |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |


Slots