RTD Converter LB5104A

Slots | |
|---|---|
| Occupied slots | 2 |
Supply | |
| Connection | backplane bus |
| Rated voltage | 12 V DC , only in connection with the power supplies LB9*** |
| Power dissipation | 0.35 W |
| Power consumption | 0.35 W |
Internal bus | |
| Connection | backplane bus |
| Interface | manufacturer-specific bus to standard com unit |
temperature input | |
| Number of channels | 4 |
| Suitable field devices | |
| Field device interface | |
| Connection | channel I: resistance/potentiometer input 1 ... 4 channel II: resistance/potentiometer input 5 ... 8 channel III: resistance/potentiometer input 9 ... 12 channel IV: resistance/potentiometer input 13 ... 16 |
| Measurement range | Pt100 (18-390 ?) (500 ? incl. line resistance) Pt200 (37-780 ?) Pt500 (92-1952 ?) Pt1000 (185-3905 ?) Ni100 (69-270 ?) Ni500 (345-1350 ?) Ni1000 (690-2700 ?) |
| Slide-wire sensor | 0 ... 10 k? |
| Measuring current | 200 µA |
| Smallest span | 50 ? for 0.1 % accuracy |
| Linearity error | 0.1 % |
| Conversion time | max. 500 ms (4 channels) max. 1 s (for 4x 3-wire Pt100) |
| Busy after download | 5 ... 15 s |
| Lead resistance | max. 50 ? per strand |
| Line fault detection | can be switched on/off for each channel via configuration tool |
Transfer characteristics | |
| Deviation | |
Indicators/settings | |
| LED indication | Power LED (P) green: supply Status LED (I) red: line fault (collective alarm) , red flashing: communication error |
| Coding | optional mechanical coding via front socket |
Directive conformity | |
| Electromagnetic compatibility | |
Conformity | |
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Environmental test | EN 60068-2-14 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Damaging gas | EN 60068-2-42 |
| Relative humidity | EN 60068-2-56 |
Ambient conditions | |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications | |
| Degree of protection | IP20 when mounted on backplane |
| Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14...1.5mm2) or screw terminals (0.08...1.5mm2) |
| Mass | approx. 150 g |
| Dimensions | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |


Slots