EasyCom Com Unit for PROFIBUS DP/DP-V1 LB8106*
Описание
Информация для заказа
Supply | |
---|---|
Connection | backplane bus |
Rated voltage | 5 V DC , only in connection with the power supplies LB9*** |
Power consumption | 2 W |
Fieldbus interface | |
Fieldbus type | PROFIBUS DP/DP-V1 |
PROFIBUS DP | |
Number of stations per bus line | max. 125 (PROFIBUS), max. 119 (service bus) |
Cyclic process data | 240 bytes input and (simultaneously) 240 bytes output |
Number of stations per bus segment | max. 31 (RS-485 standard) |
Number of repeaters between Master and Slave | max. 3 |
Supported I/O modules | all LB remote I/O modules |
Bus length | max. 1000 m (FOL, 1.5 MBaud), max. 1000 m (copper cable, 187.5 kBd), max. 200 m (copper cable, 1.5 MBd) |
Addressing | via configuration software |
PROFIBUS address | 0 ... 126 (factory standard setting: 126) |
GSE file | CGV61711.gsd/gse |
HART communication | via PROFIBUS or service bus |
Internal bus | |
Connection | backplane bus |
Redundancy | via backplane |
Indicators/settings | |
LED indicator | LED 1 (power supply): On = operating, fast flash = cold start LED 2 (collective alarm): On = internal fault, flashing = no PROFIBUS connection LED 3 (status process bus): flashing = PROFIBUS receive channel active LED 4 (status service bus): flashing = service bus receive channel active LED 5 (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation LED 6 (status process bus): flashing = PROFIBUS response channel active LED 7 (status servicebus): flashing = service bus response channel active |
Directive conformity | |
Electromagnetic compatibility | |
Conformity | |
Electromagnetic compatibility | NE 21 |
Degree of protection | IEC 60529 |
Ambient conditions | |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications | |
Degree of protection | IP20 (module) , mounted on backplane |
Connection | via backplane |
Mass | approx. 120 g |
Dimensions | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
Data for application in connection with hazardous areas | |
Certificate | PF 08 CERT 1234 X |
Directive conformity | |
International approvals | |
ATEX approval | PF 08 CERT 1234 X |
UL approval | E106378 |
IECEx approval | BVS 09.0037X |
EAC approval | Russia: RU C-IT.MIII06.B.00129 |
Marine approval |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
<img alt="" src=" http://www.filfar.by/images/MTS_lo</h3> |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
День | Время работы |
---|---|
Понедельник | 09:00-17:00 |
Вторник | 09:00-17:00 |
Среда | 09:00-17:00 |
Четверг | 09:00-17:00 |
Пятница | 09:00-17:00 |
Суббота | Выходной |
Воскресенье | Выходной |