Unicom Com Unit for PROFIBUS DP/DP-V1 FB8209H0906
Описание
Информация для заказа
Описание оборудования | |
---|---|
Unicom Com Unit for PROFIBUS DP/DP-V1 | |
Supply | |
Connection | backplane bus |
Rated voltage | 5 V DC , only in connection with the power supplies FB92** |
Power dissipation | 1.8 W |
Power consumption | 1.8 W |
Fieldbus interface | |
Fieldbus type | PROFIBUS DP/DP-V1 |
PROFIBUS DP | |
Number of stations per bus line | max. 125 (PROFIBUS), max. 119 (service bus) |
Cyclic process data | 240 bytes input and (simultaneously) 240 bytes output |
Number of stations per bus segment | max. 31 (RS-485 standard) |
Number of repeaters between Master and Slave | max. 3 |
Supported I/O modules | all FB remote I/O modules |
Configuration (240 bytes I/O) | Standard: 80 analog, 184 digital Universal 2I2O: 48 analog, 184 digital Universal 4I4O: 60 analog, 120 digital |
Bus length | max. 1000 m (FOL, 1.5 MBaud), max. 1000 m (copper cable, 187.5 kBd), max. 200 m (copper cable, 1.5 MBd) |
Addressing | via configuration software |
PROFIBUS address | 0 ... 126 (factory standard setting: 126) |
GSE file | CGV61710.gsd/gse |
HART communication | via PROFIBUS or service bus |
Internal bus | |
Connection | backplane bus |
Redundancy | via front connector |
Indicators/settings | |
LED indication | LED green (power supply): On = operating, fast flash = cold start, slow flash = HCIR loading active LED red (collective alarm): On = internal fault, flashing = no PROFIBUS connection LED yellow (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation |
Directive conformity | |
Electromagnetic compatibility | |
Conformity | |
Electromagnetic compatibility | NE 21 |
Degree of protection | IEC 60529 |
Fieldbus standard | IEC 61158-2 |
Environmental test | EN 60068-2-14 |
Shock resistance | EN 60068-2-27 |
Vibration resistance | EN 60068-2-6 |
Damaging gas | EN 60068-2-42 |
Relative humidity | EN 60068-2-56 |
Ambient conditions | |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Relative humidity | 95 % non-condensing |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications | |
Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
Connection | via backplane |
Mass | approx. 750 g |
Dimensions | 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) |
Data for application in connection with hazardous areas | |
EU-Type Examination |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
День | Время работы |
---|---|
Понедельник | 09:00-17:00 |
Вторник | 09:00-17:00 |
Среда | 09:00-17:00 |
Четверг | 09:00-17:00 |
Пятница | 09:00-17:00 |
Суббота | Выходной |
Воскресенье | Выходной |