OOO "ФилФар Технолоджи"

Universal Temperature Converter KCD2-UT2-Ex1

  Universal Temperature Converter KCD2-UT2-Ex1
Под заказТолько оптом

Цену уточняйте

  • +375 показать номер +375(44)765-55-50
  • +375(29)690-11-55

Заказ только по телефону

  • Контакты
    • Телефон:
      +375(44)765-55-50
      +375(29)690-11-55
    • Контактное лицо:
      Сергей, Владимир
    • Адрес:
      ул. Западная, д.13, каб.519, Минск, Беларусь
    • Email:
      zapros@filfar.by

Техническая спецификация в PDF  

Описание оборудования

Current output 0/4 mA ... 20 mA

General specifications

Signal typeAnalog input

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

Connectionterminals 9+, 10- or power feed module/Power Rail
Rated voltage19 ... 30 V DC
Ripplewithin the supply tolerance
Power dissipation/power consumption? 0.98 W / 0.98 W

Interface

Programming interfaceprogramming socket

Input

Connection sidefield side
Connectionterminals 1, 2, 3, 4
RTDtype Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)
type Cu10, Cu50, Cu100 (P50353-92)
type Ni100 (DIN 43760)
Thermocouplestype B, E, J, K, N, R, S, T (IEC584-1:1995)
type L (DIN43710:1985)
type TXK, TXKH, TXA (P8.585-2001)
Potentiometer0 ... 20 k? (2-wire connection), 0.8 ... 20 k? (3-wire connection)
Voltageselectable within the range -100 ... 100 mV
Input resistance? 1 M? (-100 ... 100 mV)

Output

Connection sidecontrol side
Connectionterminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+)
OutputAnalog current output

Transfer characteristics

Deviation
Reaction timeworst case value (sensor breakage and/or sensor short circuit detection enabled)
mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s

Galvanic isolation

Output/supply, programming inputfunctional insulation, rated insulation voltage 50 V AC
There is no electrical isolation between the programming input and the supply.
The programming cable provides galvanic isolation so that ground loops are avoided.

Indicators/settings

Display elementsLEDs
Configurationvia PACTware
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility

Conformity

Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1:2004

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 100 g
Dimensions12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-Type Examination CertificateBASEEFA 13 ATEX 0102 X
Inputsterminals 1, 2, 3, 4
Analog outputs, power supply, collective error
Interface
CertificateBASEEFA 13 ATEX 0103 X
Galvanic isolation
Directive conformity

International approvals

UL approval
IECEx approvalIECEx BAS 13.0057X

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 