Продавец OOO "ФилФар Технолоджи" развивает свой бизнес на Deal.by 10 лет.
Знак PRO означает, что продавец пользуется одним из платных пакетов услуг Deal.by с расширенными функциональными возможностями.
Сравнить возможности действующих пакетов
Начать продавать на Deal.by 18 отзывов
+375 (44) 765-55-50
+375 (29) 690-11-55
OOO "ФилФар Технолоджи"

Universal Temperature Converter KFD2-UT2-Ex2-1

Universal Temperature Converter KFD2-UT2-Ex2-1, фото 2
Описание
Информация для заказа

Техническая спецификация в PDF  

Описание оборудования

Voltage output 0/1 V ... 5 V

General specifications

Signal typeAnalog input

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

Connectionterminals 14+, 15- or power feed module/Power Rail
Rated voltage20 ... 30 V DC
Ripplewithin the supply tolerance
Power dissipation/power consumption? 0.8 W / 0.8 W

Interface

Programming interfaceprogramming socket

Input

Connection sidefield side
Connectionterminals 1, 2, 3; 4, 5, 6
RTDtype Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)
type Cu10, Cu50, Cu100 (P50353-92)
type Ni100 (DIN 43760)
Thermocouplestype B, E, J, K, N, R, S, T (IEC584-1:1995)
type L (DIN43710:1985)
type TXK, TXKH, TXA (P8.585-2001)
Potentiometer0 ... 20 k? (2-wire connection), 0.8 ... 20 k? (3-wire connection)
Voltageselectable within the range -100 ... 100 mV
Input resistance? 1 M? (-100 ... 100 mV)

Output

Connection sidecontrol side
Voltage output0 ... 5 V or 1 ... 5 V ; output resistance: ? 5 ? ; load: ? 10 k?
Connectionoutput I: terminals 7-, 8+
output II: terminals 10-, 11+
Fault signaldownscale 0 V or 0.5 V, upscale 5.375 V

Transfer characteristics

Deviation
Reaction timeworst case value (sensor breakage and/or sensor short circuit detection enabled)
mV: 1.2 s, thermocouples with CJC: 1.4 s, thermocouples with fixed ref. temp: 1.4 s, 3- or 4-wire RTD: 1.1 s, 2-wire RTD: 920 ms, Potentiometer: 3-wire connection 2.8 s, 2-wire connection 2.25 s

Galvanic isolation

Output/supply, programming inputfunctional insulation, rated insulation voltage 50 V AC
There is no electrical isolation between the programming input and the supply.
The programming cable provides galvanic isolation so that ground loops are avoided.

Indicators/settings

Display elementsLEDs
Configurationvia PACTware
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility

Conformity

Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1:2004

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 130 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

<img class="noprint nodialog</strong>

  • Цена: Цену уточняйте
Информация для покупателя

ООО «ФилФар Технолоджи»

220036, г. Минск, ул. Западная, д.13, к.519

Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015

Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь

УНП: 192123248

Регистрационный орган: Минский горисполком

Дата регистрации компании: 18.09.2013

Ссылка на свидетельство/лицензию

Режим работы:

ДеньВремя работы
Понедельник09:00-17:00
Вторник09:00-17:00
Среда09:00-17:00
Четверг09:00-17:00
Пятница09:00-17:00
СубботаВыходной
ВоскресеньеВыходной