Описание оборудования

Control interface unit IDENTControlCompact
with serial interface RS-232 and RS-485

General specifications

Number of read/write headsmax. 2
alternatively 1 read/write head and 1 trigger sensor
UL File NumberE87056

Functional safety related parameters

MTTFd160 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %

Indicators/operating means

LEDs 1, 2Status indicator for read/write heads
LEDs CH1, CH2green: read head detected
red: Configuration error
LED PWR/ERRgreen: power on
red: Hardware fault
LED TxDgreen: flashes in rhythm with the transmitted data
LED RxDgreen: flashes in rhythm of receiving data

Electrical specifications

Rated operating voltage20 ... 30 V DC , PELV
Ripple? 10 % at 30VDC
Current consumption? 4 A incl. read/write heads
Power consumption2 W Without read/write heads
Galvanic isolationbasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff

Interface 1

Interface typeserial
Physical RS-485
ProtocolASCII
Transfer rate1200; 2400; 4800; 9600; 19200; 38400 Bit/s

Interface 2

Interface typeserial
Physical RS 232
ProtocolASCII
Transfer rate1200; 2400; 4800; 9600; 19200; 38400 Bit/s

Directive conformity

Electromagnetic compatibility

Standard conformity

Degree of protectionIEC60529:2001

Ambient conditions

Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Climatic conditionsair humidity max. 96 %
Salt spray resistant to EN60068-2-52
Shock and impact resistanceOscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6
Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27

Mechanical specifications

Degree of protectionIP67
ConnectionRead/write heads: shielded, 4-pin, M12 connector
Power supply: M12 connector
Protective earth: M4 earthing screw
RS 232: M12 plug connection
RS485: M12 connector
Material
Installationscrew fixing
Massapprox. 300 g

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 

8 (017) 255-8-000

Или отправьте нам запрос на e-mail:  zapros@filfar.by

 

Информация для заказа
  • Цена: Цену уточняйте
Контакты
  • Телефон:
    +375(44)765-55-50
    +375(29)690-11-55
  • Контактное лицо:
    Сергей, Владимир
  • Адрес:
    ул. Западная, д.13, каб.519, Минск, Беларусь
  • Email:
    zapros@filfar.by
Карта