Control interface unit IC-KP2-1HB6-2V15B

Описание оборудования | |
|---|---|
| Control interface unit IDENTControlCompact with PROFIBUS DP interface | |
General specifications | |
| Number of read/write heads | max. 1 |
| UL File Number | E87056 |
Functional safety related parameters | |
| MTTFd | 140 a |
| Mission Time (TM) | 10 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
| LED BUS | green: Slave is at state "Data Exchange" red: Bus error |
| LED 1 | Status indicator for read/write head green: command at read/write head active yellow: approx. 1 second long, if command was successfully executed |
| LED CH1 | green: read head detected red: Configuration error |
| LED PWR/ERR | green: power on red: Hardware fault |
| Rotary switch | Address setting 00 ... 7E, FF (hexadecimal) BUS Address (high nibble): 0 ... 7, F BUS Address (low nibble): 0 ... F |
Electrical specifications | |
| Rated operating voltage | 20 ... 30 V DC , PELV |
| Ripple | ? 10 % at 30VDC |
| Current consumption | ? 4 A incl. read/write head |
| Power consumption | 2 W Without read/write head |
| Galvanic isolation | basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff |
Interface 1 | |
| Interface type | PROFIBUS |
| Physical | RS-485 |
| Protocol | PROFIBUS DP acc. to EN50170 |
| Transfer rate | 9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing |
Interface 2 | |
| Interface type | PROFIBUS |
| Physical | RS-485 |
| Protocol | PROFIBUS DP acc. to EN50170 |
| Transfer rate | 9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s 38.4 kBit/s self-synchronizing |
Directive conformity | |
| Electromagnetic compatibility | |
Standard conformity | |
| Degree of protection | IEC60529:2001 |
Ambient conditions | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Climatic conditions | air humidity max. 96 % Salt spray resistant to EN60068-2-52 |
| Shock and impact resistance | Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6 Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27 |
Mechanical specifications | |
| Degree of protection | IP67 |
| Connection | read/write head: M12 plug connection, 4-pin, screened, Power supply: M12 connector Protective earth: M4 earthing screw PROFIBUS: M12 connector, B-coded |
| Material | |
| Installation | screw fixing |
| Mass | approx. 300 g |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
8 (029) 555-8-000 | |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |


Описание оборудования