AS-Interface I/O module VBA-4E4A-G20-ZEJ/M3L-P10
Описание
Информация для заказа
Описание оборудования | |
---|---|
G20 motor control module 2 inputs/2 outputs | |
General specifications | |
Slave type | A/B slave |
AS-Interface specification | V3.0 |
Required master specification | ? V2.1 |
UL File Number | E223772 "For use in NFPA 79 Applications only" |
MTBF | 98 a |
Compatible roller motors | Itoh Denki PM*XP, Itoh Denki PM*XE |
Indicators/operating means | |
LED FAULT | error display; LED red red: communication error or address is 0 red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing |
LED PWR | AS-Interface voltage; green LED green: voltage OK green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing |
LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
LED IN | switching state (input); 2 LED yellow |
LED FUSE | Motor power supply; 2 green LEDs |
LED DIR | Motor rotation direction; yellow LED |
LED MOT | Motor active; 2 yellow LEDs |
Electrical specifications | |
Auxiliary voltage (output) | 18 ... 30 VDC PELV |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Rated operating current | ? 25 mA (without sensors) / max. 170 mA |
Input | |
Number/Type | 2 Inputs for 3-wire sensors (PNP), DC |
Supply | from AS-Interface |
Current loading capacity | 100 mA , overload and short-circuit protected |
Input current | ? 6 mA (internally limited) |
Switching point | according to DIN EN 61131-2 0 (undamped) ?0.5mA 1 (damped) ?2.0mA |
Signal delay | < 1 ms (input/AS-Interface) |
Input filter | 2ms |
Output | |
Number/Type | 2 outputs for DC roller motors (MOT1, MOT2) |
Supply | from external auxiliary voltage UAUX |
Current | 2 A , max. 5 A (<2 s) per motor |
Overload protection | fuse , I2t = 53.7 A2s |
Velocity signal | 0 ... 10 V DC Control via parameter P1:0 |
Rotation direction signal | PNP digital output low: high impedance high; ? (VAUX - 2.5V) in no-load operation |
Motor start signal | PNP digital output low: high impedance high; ? (VAUX - 2.5V) in no-load operation |
Directive conformity | |
Electromagnetic compatibility | |
Standard conformity | |
Degree of protection | EN60529:2000 |
Fieldbus standard | EN62026-2:2013 |
Input | EN 61131-2:2007 |
Emitted interference | EN61000-6-4:2007 |
AS-Interface | EN62026-2:2013 |
Noise immunity | EN61000-6-2:2005, EN61326-1:2006, EN62026-2:2013 |
Programming instructions | |
Profile | S-7.A.7 |
IO code | 7 |
ID code | A |
ID1 code | 7 |
ID2 code | 7 |
Data bits (function via AS-Interface) | input outpu |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
День | Время работы |
---|---|
Понедельник | 09:00-17:00 |
Вторник | 09:00-17:00 |
Среда | 09:00-17:00 |
Четверг | 09:00-17:00 |
Пятница | 09:00-17:00 |
Суббота | Выходной |
Воскресенье | Выходной |