AS-Interface analog module VBA-4A-G11-I/U-F

Описание оборудования | |
|---|---|
| G11 analog module 4 analog outputs | |
General specifications | |
| Slave type | Standard slave |
| AS-Interface specification | V3.0 |
| Required master specification | ? V2.1 |
| UL File Number | E223772 |
Functional safety related parameters | |
| MTTFd | 220 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
| LED AS-i/FAULT | Status display; multi-colour LED Green: normal operation Red: communication fault Flashing yellow/red: address 0 Flashing green/red: peripheral fault |
| LED ANALOG | Status of output signal; yellow LED Yellow: Output value within range Yellow flashing: lead breakage (on current output) or output value out of range |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
| LED INT/EXT | status display output supply; LED green green: output supply from AS-Interface off: output supply from auxiliary voltage |
Electrical specifications | |
| Auxiliary voltage (output) | 24 V DC ± 15 % PELV |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
| Rated operating current | ? 75 mA (without outputs) / max. 200mA |
| Protection class | III |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Output | |
| Number/Type | 4 analog outputs Current: 0...20mA Voltage: 0...10V |
| Supply | from AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) |
| Load | voltage output: min. 1 k? current output: max. 600 ? |
| Current loading capacity | ? 120 mA (signal current + actuator supply) from AS-Interface; overload and short-circuit protected ? 700 mA (signal current + actuator supply) from external bulk power supply UAUX, overload and short-circuit protected |
| Resolution | Voltage output: 3mV Current output: 6µA |
| Accuracy | 0.15 % of full-scale value |
| Temperature influence | 1 µA/K or 0,3 mV/K |
| Short-circuit current | voltage output: max. 22 mA |
Directive conformity | |
| Electromagnetic compatibility | |
Standard conformity | |
| Degree of protection | EN60529:2000 |
| Fieldbus standard | EN62026-2:2013 |
| Emitted interference | EN61000-6-4:2007 |
| AS-Interface | EN62026-2:2013 |
| Noise immunity | EN61000-6-2:2005, EN61326-1:2006, EN62026-2:2013 |
Programming instructions | |
| Profile | S-7.3.6 |
| IO code | 7 |
| ID code | 3 |
| ID1 code | F |
| ID2 code | 6 |
| Data bits (function via AS-Interface) | The transfer of the data value is based on AS-Interface Profile 7.3. |
| Parameter bits (programmable via AS-i) | function |
Ambient conditions | |
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |


Описание оборудования