Triangulation sensor (BGS) OBT60-R102-2P1-IO-0,3M-V1
Описание оборудования | |
---|---|
Triangulation sensor with background suppression | |
General specifications | |
Detection range | 10 ... 60 mm |
Detection range max. | 10 ... 80 mm |
Background suppression | starts from 80 mm |
Reference target | standard white, 100 mm x 100 mm |
Light source | LED |
Light type | modulated visible red light |
LED risk group labelling | exempt group |
Black/White difference (6 %/90 %) | approx. 3 mm |
Diameter of the light spot | approx. 4 mm at 60 mm |
Angle of divergence | approx. 5 ° |
Ambient light limit | EN 60947-5-2 : 40000 Lux |
Functional safety related parameters | |
MTTFd | 600 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
Function indicator | LED yellow: constantly on - object detected constantly off - object not detected |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC |
Ripple | max. 10 % |
No-load supply current | < 25 mA at 24 V supply voltage |
Protection class | III |
Interface | |
Interface type | IO-Link ( via C/Q = BK ) |
Device profile | Smart Sensor |
Transfer rate | COM2 (38.4 kBaud) |
IO-Link Revision | 1.1 |
Min. cycle time | 2.3 ms |
Process data witdh | Process data input 1Bit Process data output 2Bit |
SIO mode support | yes |
Device ID | 0x110515 (1115413) |
Compatible master port type | A |
Output | |
Switching type | C/Q - Pin4: NPN normally closed / dark-on, PNP normally open / light-on, IO-Link /Q - Pin2: NPN normally open / light-on, PNP normally closed / dark-on |
Signal output | 2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA , resistive load |
Usage category | DC-12 and DC-13 |
Voltage drop | ? 1.5 V DC |
Switching frequency | 500 Hz |
Response time | 1 ms |
Conformity | |
Communication interface | IEC 61131-9 |
Product standard | EN 60947-5-2 |
Approvals and certificates | |
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 |
Ambient conditions | |
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) , fixed cable -25 ... 60 °C (-13 ... 140 °F) , movable cable not appropriate for conveyor chains |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
<img class="noprint nodialog" src="https://www.ifm.com/im</strong> |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком