Active infrared scanner TopScan-S-M/L310
Описание оборудования | |
---|---|
Single or multi-beam light curtain for individual protection according to DIN18650/EN16005 | |
General specifications | |
Detection range min. | 0 ... 1500 mm |
Detection range max. | 0 ... 2500 mm |
Reference target | Minimum degree of reflection of the floor: 6 % Minimum degree of reflection to objects being detected: 0 % |
Light source | IRED |
Light type | modulated infrared light 875 nm |
Black/White difference (6 %/90 %) | < 2 % at 2000 mm sensor range |
Number of beams | 1 (number of built-in sensor modules AIR) |
Operating mode | Background evaluation |
Diameter of the light spot | 1.1 cm x 8.3 cm at 2000 mm sensor range |
Resolution | Reference object CA DIN 186850-1/EN 16005 in all applicable locations |
Functional safety related parameters | |
Safety Integrity Level (SIL) | SIL 1 |
Performance level (PL) | PL c |
Category | Cat. 2 |
MTTFd | 880 a per module |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 90 % |
Indicators/operating means | |
Function indicator | LED red/green |
Control elements | Sensing range adjuster ; Adjuster for edge monitoring left/right |
Electrical specifications | |
Operating voltage | 24 V DC +/- 20 % |
No-load supply current | 75 mA |
Input | |
Test input | active at U = 11 V DC at 30 V DC inactive at U = -3 V DC at 5 V DC |
Output | |
Switching type | Relay de-energized at object inside the scanning range |
Signal output | Relay, 1 alternator |
Switching voltage | 5 V ... 30 V AC/DC |
Switching current | max. 300 mA |
Response time | ? 70 ms |
Conformity | |
Functional safety | ISO13849-1 |
Product standard | EN 12978 ; EN 16005 ; DIN 18650 |
Approvals and certificates | |
CCC approval | CCC approval / marking not required for products rated ?36 V |
TUV approval | TUV NORD |
Ambient conditions | |
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) |
Relative humidity | Humidity at 20 °C: < 90 % Humidity at 60 °C: < 50 % |
Mechanical specifications | |
Housing length L | 310 mm |
Mounting height | max. 2500 mm |
Degree of protection | IP52 , IP54 Optional (with special seal) |
Connection | screw terminals ; Cable cross-section 0.3 mm2 ... 1.3 mm2 (AWG26-16), single-stranded/multistranded CU |
Material | |
Note | Safety fuse ? 1A (slow-blow) according to IEC60127-2 Sheet1 Recommendation: after a short circuit, check that the device is functioning correctly. |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
<img alt="" src=" http://www.filfar.by/images/</h3> |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
День | Время работы |
---|---|
Понедельник | 09:00-17:00 |
Вторник | 09:00-17:00 |
Среда | 09:00-17:00 |
Четверг | 09:00-17:00 |
Пятница | 09:00-17:00 |
Суббота | Выходной |
Воскресенье | Выходной |