Safety light grid with integrated control unit SLC-3

System components | |
|---|---|
| Emitter | SLC-3-T |
| Receiver | SLC-3-R |
General specifications | |
| Effective detection range | 0.2 ... 20 m |
| Light source | IRED |
| Light type | modulated infrared light |
| LED risk group labelling | exempt group |
| Tests | IEC/EN 61496 |
| Safety type according to IEC/EN 61496 | 4 |
| Target size | 50 mm |
| Beam spacing | 400 mm |
| Number of beams | 3 |
| Operating mode | can be selected with or without start/restart disable |
| Angle of divergence | < 5 ° |
Functional safety related parameters | |
| Safety Integrity Level (SIL) | SIL 3 |
| Performance level (PL) | PL e |
| Category | Cat. 4 |
| Mission Time (TM) | 20 a |
| PFHd | 7.27 E-9 |
| Type | 4 |
Indicators/operating means | |
| Operation indicator | 7-segment display in emitter |
| Diagnostics indicator | 7-segment display in receiver |
| Function indicator | in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready |
| Pre-fault indicator | LED orange |
| Control elements | switch for start/restart disable, transmission coding |
Electrical specifications | |
| Operating voltage | 24 V DC (-30 %/+25 %) |
| No-load supply current | Emitter: 100 mA , receiver 150 mA |
| Protection class | III |
Input | |
| Activation current | approx. 10 mA |
| Activation time | 0.03 ... 1 s |
| Test input | Reset-input for system test |
| Function input | Start release |
Output | |
| Safety output | 2 separated fail safe semiconductor outputs |
| Signal output | 1 PNP each, max. 100 mA for start readiness and OSSD status |
| Switching voltage | Operating voltage -2 V |
| Switching current | max. 0.5 A |
| Response time | 10 ms |
Conformity | |
| Functional safety | ISO13849-1 |
| Product standard | EN61496-1 ; IEC61496-2 |
Approvals and certificates | |
| CE conformity | CE |
| UL approval | cULus Listed |
| CCC approval | CCC approval / marking not required for products rated ?36 V |
| TUV approval | TUV |
Ambient conditions | |
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) |
| Storage temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Relative humidity | max. 95 %, not condensing |
Mechanical specifications | |
| Degree of protection | IP67 |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |


System components