Ordering details

Product type descriptionAZM201Z-I2-ST2-T-1P2PW-A
Article number103013489
EAN Code4030661493329
eCl@ss27-27-26-03

Approval

Approval TÜV
USA/CAN
EAC

Classification

Interlocking function:
StandardsEN ISO 13849-1, IEC 61508, IEC 62061
PLe
Control category4
PFH value1.9 x 10−9 / h
PFD value1.6 x 10−4
SILSuitable for SIL 3 applications
Mission time20 Years
Guard locking function:
StandardsISO 13849-1, IEC 61508, IEC 62061
PLd
Control category2
PFH value1.0 x 10−8 / h
PFD value8.9 x 10−4
SILSuitable for SIL 3 applications
Mission time20 Years

Global Properties

Permanent lightAZM201
StandardsIEC 60947-5-1, IEC 60947-5-3, ISO 14119, ISO 13849-1, IEC 61508, IEC 62061
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Protection ratingIII
Series-wiringup to 31 components
Length of the sensor chain200 m
Active principleRFID
Duty cycle100
Coding levels according to ISO 14119High
CodingIndividual coding, multiple teaching
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight590
Guard locking monitored (Y/N)Yes
Actuator monitored (Y/N)No
Idle assignable pushbutton and LED (Y/N)No
Response time
Actuator≤ 100
Duration of risk<>
Time to readiness<>
Recommended actuatorAZ/AZM201-B1, AZ/AZM201-B30
- Actuator≤ 100 ms
- Inputs≤ 0,5 ms

Mechanical data

Design of electrical connectionConnector M12, 8-pole
Cable section
- Min. Cable section
- Max. Cable section
AWG-Number
Mechanical life≥ 1.000.000 operations
notice
restistance to shock30 / 11
Resistance to vibration10 … 150 HZ, Amplitude 0,35 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)Yes
Emergency release (Y/N)No
Latching force30
Clamping force2000
Max. Actuating speed≤ 0,2

Ambient conditions

Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+60
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30… 95
- non-condensing
Protection classIP66, IP67 to IEC 60529
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage0,8
- Overvoltage categoryIII
- Degree of pollution3

Electrical data

Number of auxiliary contacts0
Number of safety contacts2
Cross circuit/short circuit recognition possible (Y/N)Yes
Power to unlockNo
Power to lockYes
Supply voltage
- Min. supply voltage20.4 V DC
- Max. supply voltage26.4 V DC
Switch frequency1
Rated insulation voltage32 V DC
Operating current1.2 A
Utilisation categoryDC-13
No-load current0,6 A
Device insulation≤ 2 A

Electrical data - Safety inputs

Safety inputsX1 and X2
Rated operating voltage-3 … 5 (Low)
15 … 30 (High)
Operating currenttypically 2 at 24

Electrical data - Safety outputs

Safety outputsY1 and Y2
Fuse ratingshort-circuit proof, p-type
Rated operating voltage0 … 4 under
Residual current≤ 0,5
Operating currentmax. each 0,25 A
Utilisation categoryDC-13

Electrical data - Diagnostic output

Serial diagnostics (Y/N)No
Fuse ratingp-type, short-circuit proof
Operating current0,05 A
Utilisation categoryDC-13: 24 V / 0,05 A
Wiring capacitance for serial diagnostics-
diagnostic signalsguard door closed and interlocking device locked
Operating principle of the diagnostic outputThe short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
noticeThe diagnostic output is not a safety-relevant output!

Electrical data - Solenoid control IN

Rated operating voltage Ue-3 V … 5 V (Low)
15 V … 30 V (High)
Operating current Ietypically 10 mA at 24 V, dynamically 20 mA
Control command

LED switching conditions display

LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltagegreen LED
- switching conditionyellow LED
- Error functional defectred LED

ATEX

Explosion protection categories for gasesNone
Explosion protected category for dustsNone

Dimensions

Dimensions of the sensor
- Width of sensor40 mm
- Height of sensor220
- Length of sensor50

Pin assignment

1A1 Supply voltage UB
2X1 safety input 1
3A2 GND
4Y1 safety output 1
5OUT diagnostic output
6X2 safety input 2
7Y2 safety output 2
8IN solenoid control

notice

As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required.

Included in delivery

Included in deliveryAZM201
Triangular key
Actuators must be ordered separately.

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 

8 (017) 255-8-000

Или отправьте нам запрос на e-mail:  zapros@filfar.by

 

Информация для заказа
  • Цена: Цену уточняйте
Контакты
  • Телефон:
    +375(44)765-55-50
    +375(29)690-11-55
  • Контактное лицо:
    Сергей, Владимир
  • Адрес:
    ул. Западная, д.13, каб.519, Минск, Беларусь
  • Email:
    zapros@filfar.by
Карта