Ordering details | |
---|---|
Product type description | AZM 161SK-12/12RIA-024-B6R - Ordering suffix |
Article number | 101211999 |
EAN Code | 4030661412184 |
eCl@ss | 27-27-26-03 |
Approval | |
Approval | ![]() ![]() ![]() ![]() |
Classification | |
Standards | EN ISO 13849-1 |
B10d Normally-closed contact (NC) | 2.000.000 |
Mission time | 20 Years |
notice | ![]() |
Global Properties | |
Permanent light | AZM 161I |
Standards | EN 60947-5-1, BG-GS-ET-19 |
Compliance with the Directives (Y/N) ![]() | Yes |
Number of actuating directions | 3 |
Active principle | electromechanical |
- Individual coding | |
- Coding level "High" according to ISO 14119 | |
Duty cycle | Magnet 100 |
Materials | |
- Material of the housings | glass-fibre reinforced thermoplastic, Plastic self-extinguishing, |
- Material of the actuator | Stainless steel |
- Material of the contacts | Silver |
Housing coating | None |
Weight | 485 |
Mechanical data | |
Design of electrical connection | Screw connection |
Cable section | |
- Min. Cable section | 1 x 0,25 |
- Max. Cable section | 1 x 1.5, flexible |
Mechanical life | > 1.000.000 operations |
notice | All indications about the cable section are including the conductor ferrules. |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | Yes |
Emergency release (Y/N) | No |
Latching force | 30 |
Positive break force | 20 |
positive break travel | 10 |
Clamping force | 2000 |
Max. Actuating speed | 2 |
Minimum actuating radius | 95 |
Actuating frequency | 1000 / |
Ambient conditions | |
Ambient temperature | |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +60 |
Protection class | IP67 to IEC/EN 60529 |
Electrical data | |
Design of control element | Normally open contact (NO), Opener (NC) |
Switching principle | Creep circuit element |
Number of auxiliary contacts | 2 |
Number of safety contacts | 4 |
Power to unlock | No |
Power to lock | Yes |
Rated control voltage | 24 V/DC |
Power consumption | 10 |
Rated impulse withstand voltage | 4 |
Rated insulation voltage | 250 |
Thermal test current | 6 A |
Utilisation category | AC-15: 230 V / 4 A DC-13: 24 V / 2,5 A |
Max. fuse rating | 6 A gG D-fuse To DIN EN 60269-1 |
ATEX | |
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
Miscellaneous data | |
Applications | ![]() ![]() ![]() |
Dimensions | |
Dimensions of the sensor | |
- Width of sensor | 130 |
- Height of sensor | 90 |
- Length of sensor | 30 |
notice | |
Actuating radius adjustable, minimum 95 mm, using an hexagonal key wrench 2 mm A/F (a) | |
The actuator is not available separately. | |
The axis of the hinge should be 11 mm above the top edge of the safety switch and in the same plane | |
Manual release | |
• For maintenance, installation, etc. | |
• For manual release using M5 triangular key, available as accessory | |
Included in delivery | |
Included in delivery | |
• Individually coded actuator | |
• tamperproof screws | |
• Slot sealing plugs | |
Diagram | |
![]() Note Diagram ![]() ![]() ![]() ![]() ![]() | |
Switch travel diagram | |
![]() Notes Switch travel diagram ![]() ![]() ![]() ![]() ![]() VSadjustable range of NO contact VÖadjustable range of NC contact Nafter travel | |
...-1637 | 0,3 µm gold-plated contacts |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |
Или отправьте нам запрос на e-mail: zapros@filfar.by