Ordering details

Product type descriptionMS-AZ 200ST-T-1P2P-2568
Article number103006853
EAN Code
eCl@ss27-27-26-02

Approval

Approval USA/CAN
TÜV
EAC

Classification

StandardsEN ISO 13849-1, IEC 61508
PLe
Control category4
PFH4.0 x 10-9/h
SIL3
Mission time TM20 Years
ClassificationPDF-M

Global Properties

Permanent lightAZ 200
StandardsIEC 60947-5-3, IEC 61508, EN ISO 13849-1, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Series-wiringup to 31 components
Length of the sensor chainmax. 200 m
Active principleNon-contact
Duty cycle ED100 %
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic
Housing coatingNone
Weight400
Actuator monitored (Y/N)Yes
Idle assignable pushbutton and LED (Y/N)Yes
Reaction time≤ 60
Duration of risk> 120
Time to readiness4000
Recommended actuatorAZ/AZM 200-B1

Mechanical data

Design of electrical connectionConnector M23, 12-pole
Mechanical life≥ 1.000.000 operations
Switch distance Sn6.5 mm
Ensured switch distance ON Sao4 mm
Ensured switch distance OFF Sar30 mm
hysteresismax. 1.5
Repeat accuracy R R< 0,5="">
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm
Emergency unlocking device (Y/N)No
Manual release (Y/N)No
Emergency release (Y/N)No
Latching force30
Max. Actuating speed≤ 0,2

Ambient conditions

Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+70
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Relative humidity30… 95
- non-condensing
Protection classIP67 to IEC/EN 60529
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Overvoltage categoryIII
- Degree of pollution3

Electrical data

Number of auxiliary contacts0
Number of safety contacts2
Cross circuit/short circuit recognition possible (Y/N)Yes
Switch frequency1
Rated insulation voltage Ui32 VDC
Rated operating voltage Ue
- Min. Rated operating voltage20.4 VDC
- Max. Rated operating voltage26.4 VDC
Operating current Ie0,7 A
Utilisation categoryDC-13
No-load current I00,1 A
Device insulation≤ 4 A

Electrical data - Safety inputs

Safety inputsX1 and X2
Rated operating voltage Ue- 3 V … 5 V (Low)
15 V … 30 V (High)
Operating current Ie> 2 mA / 24 V

Electrical data - Safety outputs

Safety outputsY1 and Y2
Fuse ratingshort-circuit proof
Design of control outputp-type
Rated operating voltage0 V … 4 V under Ue
Residual current Ir≤ 0,5 mA
Operating current Ie0,25 A
Utilisation categoryDC-13: 24 V / 0,25 A

Electrical data - Diagnostic output

Serial diagnostics (Y/N)No
Fuse ratingshort-circuit proof
Design of control outputp-type
Operating current Ie0,05 A
Utilisation categoryDC-13: 24 V / 0,05 A
Wiring capacitance for serial diagnostics-
diagnostic signalsguard door closed
Operating principle of the diagnostic outputThe short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
noticeThe diagnostic output is not a safety-relevant output!

LED switching conditions display

LED switching conditions display (Y/N)Yes
LED switching conditions display
- Supply voltagegreen LED
- switching conditionyellow LED
- Error functional defectred LED

ATEX

Explosion protection categories for gasesNone
Explosion protected category for dustsNone

Dimensions

Dimensions of the sensor
- Width of sensor40
- Height of sensor220
- Length of sensor50

Pin assignment

1A1 Supply voltage UB
2X1 Safety input 1
3A2 GND
4Y1 Safety output 1
5OUT Diagnostic output
6X2 Safety input 2
7Y2 Safety output 2
8IN serial diagnostic input
9without function

Included in delivery

Actuators must be ordered separately.

Diagram



Note Diagram
positive break NC contact
active
no active
Normally-open contact
Normally-closed contact

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 

8 (017) 255-8-000

Или отправьте нам запрос на e-mail:  zapros@filfar.by

 

Информация для заказа
  • Цена: Цену уточняйте
Контакты
  • Телефон:
    +375(44)765-55-50
    +375(29)690-11-55
  • Контактное лицо:
    Сергей, Владимир
  • Адрес:
    ул. Западная, д.13, каб.519, Минск, Беларусь
  • Email:
    zapros@filfar.by
Карта