Ordering details | |
---|---|
Product type description | EX-TV10S 335-02Z-3D |
Article number | 101193079 |
EAN Code | 4030661354750 |
eCl@ss | 27-27-26-01 |
Approval | |
Approval | ![]() |
Classification | |
Standards | ISO 13849-1 |
B10d Normally-closed contact (NC) | 20.000.000 |
Mission time | 20 Years |
notice | ![]() |
Global Properties | |
Permanent light | EX-TV.S 335 |
Standards | EN 60947-5-1, BG-GS-ET-15, EN 60079-0, EN 60079-31 |
Compliance with the Directives (Y/N) ![]() | Yes |
Materials | |
- Material of the housings | light alloy die-casting |
- Material of the actuator | stainless steel, 1.4301 |
- Material of the contacts | Silver |
Housing coating | painted |
Weight | 116 |
Mechanical data | |
Design of electrical connection | Screw connection |
Cable entry M 20 x 1.5 | 1 |
Cable section | |
- Min. Cable section | 0,75 |
- Max. Cable section | 2.5 |
Mechanical life | > 1.000.000 operations |
Switching frequency | 1000 |
notice | All indications about the cable section are including the conductor ferrules. |
Design of actuating element | Other |
Shaft bore | Ø 10 |
Positive break angle | 7 |
Positive break torque | 60 |
Positive break force | 5 N for each NC contact fitted |
positive break travel | 10.7 |
Impact energy | 4 |
Actuating speed | max. 1 m/s |
Ambient conditions | |
Ambient temperature | |
- Min. environmental temperature | −20 |
- Max. environmental temperature | +60 |
Protection class | IP67 |
Electrical data | |
Design of control element | Opener (NC) |
Switching principle | Creep circuit element |
Number of auxiliary contacts | 0 |
Number of safety contacts | 2 |
Rated impulse withstand voltage | 6 |
Rated insulation voltage | 500 |
Thermal test current | 10 A |
Utilisation category | AC-15: 230 V / 4 A, DC-13: 24 V / 4 A |
Max. fuse rating | 6 A gG D-fuse |
ATEX | |
EX-marking | EX II 3D Ex tc IIIC T90°C Dc X |
Explosion protection categories for gases | None |
Explosion protection Zones for gases | None |
Explosion protected category for dusts | ATEX dust ex-protection, Cat. 3 |
Explosion protection Zones for dusts | 22 |
Dimensions | |
Dimensions of the sensor | |
- Width of sensor | 40.5 |
- Height of sensor | 107 |
- Length of sensor | 65.3 |
notice | |
Setting assistance | Grub screw for location, shaft pre-drilled for pin |
Universal joint available to compensate for axial displacement (only for shaft bore 10 mm) | |
By turning the head in 90° steps, 8 actuating planes are possible. A Torx T10 screwdriver is needed for this purpose. Even when the screw is removed, the head is self-retaining. The switch can still not be tampered. | |
Diagram | |
![]() Note Diagram ![]() ![]() ![]() ![]() ![]() | |
Switch travel diagram | |
![]() Notes Switch travel diagram ![]() ![]() ![]() ![]() ![]() VSadjustable range of NO contact VÖadjustable range of NC contact Nafter travel |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |