OOO "ФилФар Технолоджи"

101204613 | CSS 11-30S-SD-M-ST

  101204613 | CSS 11-30S-SD-M-ST
Под заказТолько оптом

Цену уточняйте

  • +375 показать номер +375(44)765-55-50
  • +375(29)690-11-55

Заказ только по телефону

  • Контакты
    • Телефон:
      +375(44)765-55-50
      +375(29)690-11-55
    • Контактное лицо:
      Сергей, Владимир
    • Адрес:
      ул. Западная, д.13, каб.519, Минск, Беларусь
    • Email:
      zapros@filfar.by

Техническая спецификация в PDF  

Ordering details

Product type descriptionCSS 11-30S-SD-M-ST
Article number101204613
EAN Code4030661381657
eCl@ss27-27-24-01

Approval

Approval TÜV
USA/CAN

Classification

StandardsEN ISO 13849-1, IEC 61508, IEC 60947-5-3
PLup e
Control categorybis 4
PFH3.6 x 10 -9/h
SILbis 3
Mission time20 Years
ClassificationPDF-M

Global Properties

Permanent lightCSS 30S
StandardsIEC 60947-5-3, IEC 61508
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
FunctionSensor for series wiring
Series-wiringup to 31 components
Length of the sensor chainmax. 200 m
Active principleinductive
Materials
- Material of the housingsStainless steel
Housing construction formcylinder, thread
Weight248
Diagnostic output (Y/N)Yes
Reaction time<>
Duration of risk<>
Cascadable (Y/N)Yes
Recommended actuatorCST 30S-1

Mechanical data

mechanical installation conditionsnot flush
Actuating planesActuation from top
Active areafront
Switch distance Sn11 mm
Ensured switch distance ON Sao8 mm
Ensured switch distance OFF Sar15 mm
hysteresis< 2="">
Repeat accuracy R R< 1="">
restistance to shock30 g / 11 ms
Resistance to vibration10 … 55 HZ, Amplitude 1 mm

Ambient conditions

Ambient temperature
- Min. environmental temperature−25
- Max. environmental temperature+65
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+85
Protection classIP65, IP67 to IEC/EN 60529
IP69K to DIN 40050-9
Protection ratingII
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp0,8 kV
- Overvoltage categoryIII
- Degree of pollution3

Electromagnetic compatibility (EMC)

EMC ratingto IEC 61000-6-2
Interfering radiationto IEC 61000-6-4

Electrical data

Cross circuit/short circuit recognition possible (Y/N)Yes
Voltage typeDC
Switch frequency3
Rated insulation voltage Ui32 VAC/DC
Rated operating voltage Ue (stabilised PELV)
- Min. Rated operating voltage20.4 VDC
- Max. Rated operating voltage26.4 VDC
Operating current Ie0,6 A
No-load current I00,1 A
Required rated short-circuit current100 A
Device insulation (Circuit breaker)2 A
noticeThe cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Electrical data - Safety inputs

Safety inputsX1 and X2

Electrical data - Safety outputs

Safety outputsY1 and Y2
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of secure semi-conductor outputs2
Max. output current at secured output0,25 A
Rated operating voltagemin. (Ue − 1 V)
Residual current Ir< 0,5="">
Operating current Iemax. 0,25 A
Minimum operating current Im0,5 mA
Utilisation categoryDC-12: 24 V / 0,25 A
DC-13: 24 V / 0,25 A
Voltage drop Ud< 1="">

Electrical data - Diagnostic output

Serial diagnostics (Y/N)Yes
Fuse ratingshort-circuit proof
Design of control outputp-type
Number of semi-conductor outputs with signaling function1
Rated operating voltagemin. (Ue − 5 V)
Operating current Iemax. 0,05 A
Voltage drop Ud< 5="">
Utilisation categoryDC-12: 24 V / 0,05 A
DC-13: 24 V / 0,05 A
Wiring capacitance for serial diagnosticsmax. 50 nF

LED switching conditions display

LED switching conditions display (Y/N)Yes
Number of LED´s2

ATEX

Explosion protection categories for gasesNone
Explosion protected category for dustsNone

Dimensions

Dimensions of the sensor
- Length of sensor99.5
- Diameter of sensorM30

Pin assignment

1 - A1 Ue(1)
2 - X1 Safety input 1(2)
3 - A2 GND(3)
4 - Y1 Safety output 1(4)
5 - SD serial diagnostic output(5)
6 - X2 Safety input 2(6)
7 - Y2 Safety output 2(7)
8 - IN serial diagnostic input(8)

notice

Requirements for the safety monitoring moduleThe safety monitoring module must tolerate internal functional tests of the safety outputs for 250 μs –1500 μs.
The 250 μs switch-off time of the safety sensor additionally will be extended depending on the cable length and the capacity of the cable used. Typically, a switch-off time of 500 μs is reached with a 100 m connecting cable.

Included in delivery

Actuators must be ordered separately.
Mounting accessories Nuts M 18 x 12 piece

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 

8 (017) 255-8-000

Или отправьте нам запрос на e-mail:  zapros@filfar.by

 

Информация для заказа
  • Цена: Цену уточняйте
Контакты
  • Телефон:
    +375(44)765-55-50
    +375(29)690-11-55
  • Контактное лицо:
    Сергей, Владимир
  • Адрес:
    ул. Западная, д.13, каб.519, Минск, Беларусь
  • Email:
    zapros@filfar.by
Карта