Ordering details | |
---|---|
Product type description | SLC445-ER-0250-14-01 |
Article number | 103005387 |
EAN Code | |
eCl@ss | 27-27-27-04 |
Approval | |
Approval | ![]() ![]() ![]() |
Classification | |
Standards | EN ISO 13849-1, EN 62061 |
PL | up e |
Control category | up 4 |
PFH value | 5.14 x 10-9 / |
SIL | up 3 |
Mission time | 20 Years |
Global Properties | |
Permanent light | SLC445 Sicherheits-Lichtvorhang |
Standards | EN 61496-1; CLC/TS 61496-2 |
Compliance with the Directives (Y/N) ![]() | Yes |
Operating resource protection class | Protection class 3 |
Safety type in accordance with IEC 61496-1 | 4 |
Materials | |
- Material of the housings | Aluminium |
Weight | 500 |
Beam coding (Y/N) | Yes |
Protection field height | 250 |
Range of the protection field | 300 - 7000 |
Reaction time | 10 |
Wave length of the sensors | 880 |
Fade-out is possible (Y/N) | Yes |
Override possible (Y/N) | Yes |
reduced resolution (Y/N) | Yes |
Clock control possible (Y/N) | Yes |
Muting possible (Y/N) | Yes |
Restart block (Y/N) | Yes |
Master/slave function | No |
Cascadable (Y/N) | No |
Monitoring function of downstream devices (Y/N) | Yes |
Recommended safety-monitoring module | Series SRB 301 |
Mechanical data | |
Detection ability for test bodies | 14 |
Number of beams | 24 |
Design of electrical connection | Connector |
- Wiring of the transmitter | connector plug M12, 4-pole |
- Wiring of the receiver | connector plug M12, 12-pole |
Cable length | 100 |
Ambient conditions | |
Ambient temperature | |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +50 |
Storage and transport temperature | |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +70 |
Protection class | IP67 to IEC/EN 60529 |
Electrical data | |
Design of output switching element OSSD | PNP |
Power consumption | |
- Power consumption Transmitter | <> |
- Power consumption Receiver | <> |
Voltage type | DC |
Switching voltage of the OSSD in high state | 24 ± 10 |
Integrated contactor control (Y/N) | Yes |
Outputs | |
Max. output current at secured output | 250 |
Electrical data - Safety outputs | |
Number of secure semi-conductor outputs | 2 |
Number of secure outputs with contact | 0 |
LED switching conditions display | |
LED switching conditions display (Y/N) | Yes |
- Status and diagnostics | Yes |
- 7-segment display | Yes |
ATEX | |
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
Dimensions | |
Dimensions of the sensor | |
- Width of sensor | 27.8 |
- Height of sensor | Transmitter: 331 / Receiver: 341 |
- Length of sensor | 33 |
notice | |
In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. | |
Included in delivery | |
Delivery scope of disposable system | Transmitter + receiver, Mounting angle |