OOO "ФилФар Технолоджи"

101209850 | EX-T3Z 068-22YR

  101209850 | EX-T3Z 068-22YR
Под заказТолько оптом

Оптовые цены уточняйте

  • +375 показать номер +375 (44) 765-55-50
  • +375 (29) 690-11-55

Заказ только по телефону

  • Контакты
    • Телефон:
      +375 (44) 765-55-50
      +375 (29) 690-11-55
    • Контактное лицо:
      Сергей, Владимир
    • Адрес:
      ул. Западная, д.13, каб.519, Минск, 220036, Беларусь
    • Email:
      zapros@filfar.by

Техническая спецификация в PDF  

Ordering details

Product type descriptionEX-T3Z 068-22YR - Ordering suffix
Article number101209850
EAN Code4030661386430
eCl@ss27-37-12-90

Approval

ApprovalEEX
IECEx
INMETRO

Classification

StandardsEN ISO 13849-1
B10d Normally-closed contact (NC)100.000
Mission time20 Years
notice

Global Properties

Permanent lightEX-T3Z 068
StandardsEN 60947-5-1, EN 60947-5-5, EN ISO 13850, EN 60079-0, EN 60079-31, ABNT NBR IEC 60947-5-1, ABNT NBR IEC 60947-5-5, ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-31
Compliance with the Directives (Y/N) Yes
Materials
- Material of the housingscast iron, painted
- Material of the covercast iron, painted
- Material of the contactsSilver
Weight4650
Emergency-Stop button (Y/N)No

Mechanical data

Design of electrical connectionScrew connection
Cable section
- Min. Cable section0,75
- Max. Cable section1.5
Mechanical life50000 operations
noticeAll indications about the cable section are including the conductor ferrules.
Actuating forcemax. 50 N (30 N in direction of rope)
Indicator lamp (Y/N)No
Key reset (Y/N)No
Pull-ring reset (Y/N)Yes
Positive break angle32 °
Positive break torque18
Positive break force50
Length of wiremax. 2 x 50 m

Ambient conditions

Ambient temperature
- Min. environmental temperature−20
- Max. environmental temperature+60
Protection classIP65, IP66 to IEC/EN 60529
ABNT NBR IEC 60529

Electrical data

Design of control elementNormally open contact (NO), Opener (NC)
Switching principleSnap switch element
Number of auxiliary contacts2
Number of safety contacts2
Rated impulse withstand voltage Uimp4 kV
Rated insulation voltage Ui250 V
Thermal test current Ithe10 A
Utilisation categoryAC-15: 230 V / 2,5 A,
DC-13: 24 V / 6 A
Max. fuse rating6 A gG D-fuse

ATEX

EX-markingEX II 2D Ex tb IIIC T90°C Db
Explosion protection categories for gasesNone
Explosion protection Zones for gasesNone
Explosion protected category for dusts2D
Explosion protection Zones for dusts21

notice

At 3 m distance intermediate wire supports are required, see accessories

Switch travel diagram



Notes Switch travel diagram
Contact closed
Contact open
Setting range
Break point
Positive opening sequence/- angle
VSadjustable range of NO contact
VÖadjustable range of NC contact
Nafter travel

Ordering suffix

...-1637 0,3 µm gold-plated contacts

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 

8 (017) 255-8-000

Или отправьте нам запрос на e-mail:  zapros@filfar.by

 

Информация для заказа
  • Цена: Оптовые цены уточняйте
Контакты
  • Телефон:
    +375 (44) 765-55-50
    +375 (29) 690-11-55
  • Контактное лицо:
    Сергей, Владимир
  • Адрес:
    ул. Западная, д.13, каб.519, Минск, 220036, Беларусь
  • Email:
    zapros@filfar.by
Карта