101211816 | EX-TS335-20Y

Описание
Информация для заказа
Ordering details | |
|---|---|
| Product type description | EX-TS335-20Y |
| Article number | 101211816 |
| EAN Code | |
| eCl@ss | 27-27-26-01 |
Approval | |
| Approval | ATEX IECEx INMETRO |
Classification | |
| Standards | EN ISO 13849-1 |
| Mission time | 20 Years |
| notice | ![]() |
Global Properties | |
| Permanent light | EX-T335 Druckbolzen S |
| Standards | EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-31, EN 60947-5-1, BG-GS-ET-15 |
Compliance with the Directives (Y/N) ![]() | Yes |
| Suitable for safety functions (Y/N) | No |
| Actuator type | B to EN 50041 |
| Materials | |
| - Material of the housings | zinc die-cast |
| - Material of the contacts | Silver |
| Housing coating | painted |
| Housing construction form | Norm construction design |
| Weight | 320 |
Mechanical data | |
| Design of electrical connection | Screw connection |
| Cable cross-section of the cable glands | |
| - Min. Cable cross-section of the cable glands | 7 |
| - Max. Cable cross-section of the cable glands | 12 |
| Cable section | |
| - Min. Cable section | 1 |
| - Max. Cable section | 2.5 |
| AWG-Number | 13 |
| Mechanical life | > 1.000.000 operations |
| Switching frequency | 1800 |
| notice | All indications about the cable section are including the conductor ferrules. |
| Design of actuating element | Plunger |
| Actuating force | 17 |
| Bounce duration | <> |
| Switchover time | in accordance with actuating speed |
| Impact energy | 7 |
| Actuating speed for vertical actuation | |
| - Min. Actuating speed | |
| - Max. Actuating speed | 0,5 |
Ambient conditions | |
| Ambient temperature | |
| - Min. environmental temperature | −20 |
| - Max. environmental temperature | +55 °C at Cable section 2.5 +50 °C at Cable section 1 mm |
| Protection class | IP65 |
Electrical data | |
| Design of control element | Normally open contact (NO) |
| Switching principle | Slow action |
| Number of auxiliary contacts | 2 |
| Number of safety contacts | 0 |
| Rated impulse withstand voltage | 4 |
| Rated insulation voltage | 250 |
| Thermal test current | 5 A |
| Utilisation category | AC-1 |
| Max. fuse rating | 6 A gG D-fuse |
ATEX | |
| EX-marking | EX II 2D Ex tb IIIC T80°C Db EX II 2G Ex d e IIC T6 Gb |
| Explosion protection categories for gases | 2G |
- Цена: Цену уточняйте
Информация для покупателя
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |

Ordering details