Ordering details | |
---|---|
Product type description | SVE3/SR/xxxoo/oo-24VDC |
Article number | SVE3/SR/xxxoo/oo-24VDC |
EAN Code | |
notice | In the order/inquiry, the requested lock number "xxx" as well as the colours "oo/oo" of the key head must be specified (e.g. SVE3/SR/119RT/RT/119RT/RT/119RT/RT-24VDC)! The colour, which is indicated first after the lock number always is the key had half with the observation window for the lock number engraved on the key. If no lock number is indicated in the order/inquiry, we will supply a lock number at our discretion. The user must ensure that lock numbers are not assigned twice in a single plant (factory site)! The user must ensure that no double key bit numbers are allocated on one site (company site)! |
eCl@ss | 27-27-26-03 |
Classification | |
Standards | EN ISO 13849-1 |
B10d Normally-closed contact (NC) | 100.000 |
Mission time | 20 Years |
notice | ![]() |
Global Properties | |
Permanent light | Schlüssel-Wahlschalter |
Standards | IEC/EN 60947-1, IEC 60947-5-1, EN 1088 |
Compliance with the Directives (Y/N) ![]() | Yes |
Number of key selector switch | 3 |
Active principle | electromechanical |
Duty cycle | Magnet 100 |
Materials | |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
- Material of the contacts | Silver |
Housing coating | None |
Enclosure color | Black / Silver |
Color | |
- Colour of the key grip | oo/oo![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() and all combinations resulting thereof |
- Colour of the key | ![]() |
Weight | 750 |
Key number | xxx |
Key selector switch position | left, centered, right |
Locking system | Included in standard version |
Mechanical data | |
Connection type | Screw connection |
Cable section | |
- Min. Cable section | 0,25 |
- Max. Cable section | 2.5 |
Mechanical life | 100.000 operations |
notice | All indications about the cable section are including the conductor ferrules. |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | Yes |
Emergency release (Y/N) | No |
Ambient conditions | |
Ambient temperature | |
- Min. environmental temperature | 0 |
- Max. environmental temperature | +50 |
Protection class | IP65 / IP20 to IEC/EN 60529 |
Electrical data | |
Design of control element | Normally open contact (NO), Opener (NC) |
Switching principle | Creep circuit element |
Number of auxiliary contacts | 4 |
Number of safety contacts | 2 |
Power to unlock | Yes |
Power to lock | No |
Rated control voltage | 24 |
Power consumption | 8.5 |
Rated impulse withstand voltage | 2.5 |
Rated insulation voltage | 250 |
Thermal test current | 4 A |
Utilisation category | AC-15: 230 V / 4 A, DC-13: 24 V / 4 A |
Max. fuse rating | 4 A gG D-fuse To DIN EN 60269-1 |
notice | NC contacts in series |
ATEX | |
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
Dimensions | |
Dimensions of the sensor | |
- Width of sensor | 96 |
- Height of sensor | 171 |
- Length of sensor | 144 |
Included in delivery | |
Key and triangular tool included in delivery (incl. 1 key for emergencies) | |
notice - Operating principle | |
see drawing: Operating principle | Key 1-3 in Pos. 1, magnet de-energised: key-operated switch locked, NC contacts closed, key not withdrawable Key 1-3 in Pos. 1, magnet energised NC contact open: key-operated switch unlocked, NC contacts closed, key not withdrawable Key 1-3 in Pos. 2, magnet energised NC contact open: key-operated switch unlocked, NC contacts open, key withdrawable Triangular tool for manual release in Pos. 3: key-operated switch mechanically locked, magnet non-operational, NC contact open Triangular tool for manual release in Pos.4: magnet operational |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |
Или отправьте нам запрос на e-mail: zapros@filfar.by