OOO "ФилФар Технолоджи"

101170038 | AES 1136

  101170038 | AES 1136
Под заказТолько оптом

Цену уточняйте

  • +375 показать номер +375(44)765-55-50
  • +375(29)690-11-55

Заказ только по телефону

  • Контакты
    • Телефон:
      +375(44)765-55-50
      +375(29)690-11-55
    • Контактное лицо:
      Сергей, Владимир
    • Адрес:
      ул. Западная, д.13, каб.519, Минск, Беларусь
    • Email:
      zapros@filfar.by

Техническая спецификация в PDF  

Ordering details

Product type descriptionAES 1136
Article number101170038
EAN Code4030661296937
eCl@ss27-37-19-01

Approval

Approval BG
USA/CAN
EAC

Classification

StandardsEN ISO 13849-1, IEC 61508
PLup d
Control categoryup 3
PFH value1.0 x 10-7/h
SILup 2
Mission time20 Years

Global Properties

Permanent lightAES 113x
StandardsIEC/EN 60204-1, IEC 60947-5-3, IEC 61508, BG-GS-ET-14, BG-GS-ET-20
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-3, BG-GS-ET-14
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, ventilated
- Material of the contactsAg-Ni, 0,2 µm gold flashed
Weight155
Start conditionsAutomatic
Start input (Y/N)No
Feedback circuit (Y/N)No
Start-up test (Y/N)Yes
Reset after disconnection of supply voltage (Y/N)No
Automatic reset function (Y/N)Yes
Reset with edge detection (Y/N)No
Pull-in delay
- ON delay with automatic startadjustable 0,1 / 1.0 s
Drop-out delay
- Drop-out delay in case of emergency stop<>

Mechanical data

Connection typeScrew connection
Cable section
- Min. Cable section0,25
- Max. Cable section2.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)No
Mechanical life20.000.000 operations
Electrical lifetime150.000 operations for 230 VAC, 5 A (cos φ = 1)
restistance to shock30 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm, ± 15 %

Ambient conditions

Ambient temperature
- Min. environmental temperature0
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+70
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4.8 kV
- Overvoltage categoryIII To VDE 0110
- Degree of pollution2 To VDE 0110

Electromagnetic compatibility (EMC)

EMC rating10 V/m

Electrical data

Rated DC voltage for controls
- Max. rated DC voltage for controls20.4
- Max. rated DC voltage for controls27.6
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz-
- Max. rated AC voltage for controls, 50 Hz-
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz-
- Max. rated AC voltage for controls, 60 Hz-
Contact resistancemax. 100 mΩ
Power consumption<>
Type of actuationDC
Switch frequency1
Rated insulation voltage Ui250 V
Rated operating voltage Ue24 VDC ±15%
Thermal test current Ithe6 A
Operating current Ie0,2 A
Electronic protection (Y/N)No

Inputs

Monitored inputs
- Short-circuit recognition (Y/N)optional
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)Yes
Number of shuttersadjustable 1 - >0
Number of openersadjustable 1 - >2
Input resistanceapprox. 4000 Ω at GND
Input signal "1"10 … 30 VDC
Input signal "0"0 … 2 VDC
Cable length1000 m with 0,75 mm² (for Rated voltage)

Outputs

Stop category0
Number of safety contacts1
Number of auxiliary contacts0
Number of signalling outputs2
Switching capacity
- Switching capacity of the safety contactsmin. 10 mA, max. 6 A
- Switching capacity of the signaling/diagnostic outputsmin. Ue −4V / Y1, Y2: max. 100 mA
Fuse rating
- Protection of the safety contacts6 A gG D-fuse
- Fuse rating for the signaling/diagnostic outputsshort-circuit proof
Signalling outputY1: Authorized operation, safety contacts on;
Y2: No authorised operation, safety contacts off
Utilisation category To EN 60947-5-1AC-15: 230 V / 3 A
DC-13: 24 V / 2 A
Number of undelayed semi-conductor outputs with signaling function2
Number of undelayed outputs with signaling function (with contact)0
Number of delayed semi-conductor outputs with signaling function.0
Number of delayed outputs with signalling function (with contact).0
Number of secure undelayed semi-conductor outputs with signaling function0
Number of secure, undelayed outputs with signaling function, with contact.0
Number of secure, delayed semi-conductor outputs with signaling function0
Number of secure, delayed outputs with signaling function (with contact).0

LED switching conditions display

LED switching conditions display (Y/N)Yes
Number of LED´s1

Integral system diagnosis $missingShortName$

Integral system diagnosis ISD
- The following faults are registered by the safety monitoring modules and indicated by ISD
- Failure of door contacts to open or close
- Cross-wire or short-circuit monitoring of the switch connections
- Interruption of the switch connections
- Failure of the safety relay to pull-in or drop-out
- Fault on the input circuits or the relay control circuits of the safety monitoring module

Miscellaneous data

Applications Safety sensor
Guard system

Dimensions

Dimensions
- Width22.5 mm
- Height100 mm
- Depth121 mm

notice

Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

notice - Wiring example

To secure a guard door up to PL 3 and Category #03#
Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range
If one or two external relays or contactors are used to switch the load, the system can then only be classified in Category 3 to EN ISO 13849-1, if exclusion of the fault “Failure of the external contactors” can be substantiated and is documented, e.g. by using reliable down-rated contactors. A second contactor leads to an increase in the level of security by redundant switching to switch the load off.
Modification for 2 NC contacts:
The safety monitoring module can be modified to monitor two NC contacts by bridging the terminals A1 and X1. The short-circuit recognition between connections then becomes inoperative.
Expansion of enable delay time:
The enable delay time can be increased from 0,1 s to 1,0 s by changing the position of a jumper link connection under the cover of the unit.
The wiring diagram is shown with guard doors closed and in de-energised condition.
The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 

8 (017) 255-8-000

Или отправьте нам запрос на e-mail:  zapros@filfar.by

 

Информация для заказа
  • Цена: Цену уточняйте
Контакты
  • Телефон:
    +375(44)765-55-50
    +375(29)690-11-55
  • Контактное лицо:
    Сергей, Владимир
  • Адрес:
    ул. Западная, д.13, каб.519, Минск, Беларусь
  • Email:
    zapros@filfar.by
Карта