OOO "ФилФар Технолоджи"

101128795 | AES 1102.1

  101128795 | AES 1102.1
Под заказТолько оптом

Цену уточняйте

  • +375 показать номер +375(44)765-55-50
  • +375(29)690-11-55

Заказ только по телефону

  • Контакты
    • Телефон:
      +375(44)765-55-50
      +375(29)690-11-55
    • Контактное лицо:
      Сергей, Владимир
    • Адрес:
      ул. Западная, д.13, каб.519, Минск, Беларусь
    • Email:
      zapros@filfar.by

Техническая спецификация в PDF  

Ordering details

Product type descriptionAES 1102.1
Article number101128795
EAN Code4030661059129
eCl@ss27-37-19-01

Approval

Approval BG
USA/CAN
EAC

Classification

StandardsEN ISO 13849-1, IEC 61508
PLup c
Control categoryup 1
PFH value1.14 x 10-6/h
- noticeup to max. 50.000 switching cycles/year and at max. 80% contact load
SILup 1
Mission time20 Years

Global Properties

Permanent lightAES 1102
StandardsIEC/EN 60204-1, IEC 60947-5-3, IEC 61508, BG-GS-ET-14, BG-GS-ET-20
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-3, BG-GS-ET-14
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, ventilated
- Material of the contactsAgCdO
Weight164
Start conditionsAutomatic
Start input (Y/N)No
Feedback circuit (Y/N)No
Start-up test (Y/N)No
Reset after disconnection of supply voltage (Y/N)Yes
Automatic reset function (Y/N)Yes
Reset with edge detection (Y/N)No
Drop-out delay
- Drop-out delay in case of emergency stop<>

Mechanical data

Connection typeScrew connection
Cable section
- Max. Cable section2.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)No
Mechanical life3.000.000 operations
Electrical lifetime100.000 operations for 230 VAC, 5 A (cos φ = 1)
restistance to shock30 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm, ± 15 %

Ambient conditions

Ambient temperature
- Min. environmental temperature0
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+70
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4 kV
- Overvoltage categoryIII To VDE 0110
- Degree of pollution2 To VDE 0110

Electromagnetic compatibility (EMC)

EMC ratingconforming to EMC Directive

Electrical data

Rated DC voltage for controls
- Max. rated DC voltage for controls-
- Max. rated DC voltage for controls-
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz93.5
- Max. rated AC voltage for controls, 50 Hz121
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz93.5
- Max. rated AC voltage for controls, 60 Hz121
Contact resistancemax. 100 mΩ
Power consumption2.4
Type of actuationAC
Switch frequency10
Rated insulation voltage Ui250 V
Rated operating voltage Ue110 V
Thermal test current Ithe4 A
Operating current Ie0,1 A
Electronic protection (Y/N)No

Inputs

Monitored inputs
- Wire breakage detection (Y/N)Yes
- Short-circuit recognition (Y/N)No
- Earth connection detection (Y/N)No
Number of shutters2
Number of openers4
Input resistance-
Input signal "1"-
Input signal "0"-
Cable length1000 m with 0,75 mm² (for Rated voltage)

Outputs

Stop category0
Number of safety contacts1
Number of auxiliary contacts0
Number of signalling outputs0
Switching capacity
- Switching capacity of the safety contactsmax. 4 A / 6 A
Fuse rating
- Protection of the safety contacts4 A gG D-fuse / 6 A
Utilisation category To EN 60947-5-1AC-15: 250 V / 1,5 A
DC-13: 24 V / 1 A
Number of undelayed semi-conductor outputs with signaling function0
Number of undelayed outputs with signaling function (with contact)0
Number of delayed semi-conductor outputs with signaling function.0
Number of delayed outputs with signalling function (with contact).0
Number of secure undelayed semi-conductor outputs with signaling function0
Number of secure, undelayed outputs with signaling function, with contact.0
Number of secure, delayed semi-conductor outputs with signaling function0
Number of secure, delayed outputs with signaling function (with contact).0

LED switching conditions display

LED switching conditions display (Y/N)Yes
Number of LED´s1
LED switching conditions display
- The integrated LEDs indicate the following operating states.
- Authorized operation

Miscellaneous data

Applications Safety sensor
Guard system

Dimensions

Dimensions
- Width22.5 mm
- Height75 mm
- Depth110 mm

notice

Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

notice - Wiring example

To secure one or a number of guard doors up to PL c and Category 1
Monitoring a number of guard doors using magnetic safety sensors BNS range
The wiring diagram is shown with guard doors closed and in de-energised condition.

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 

8 (017) 255-8-000

Или отправьте нам запрос на e-mail:  zapros@filfar.by

 

Информация для заказа
  • Цена: Цену уточняйте
Контакты
  • Телефон:
    +375(44)765-55-50
    +375(29)690-11-55
  • Контактное лицо:
    Сергей, Владимир
  • Адрес:
    ул. Западная, д.13, каб.519, Минск, Беларусь
  • Email:
    zapros@filfar.by
Карта