Ordering details

Product type descriptionFWS 1205B
Article number101170054
EAN Code4030661297163
eCl@ss27-37-19-01

Approval

Approval BG
USA/CAN
EAC

Classification

StandardsEN ISO 13849-1, IEC 61508
PLup d
Control categoryup 3
PFH value1.0 x 10-7/h
SILup 2
Mission time20 Years

Global Properties

Permanent lightFWS 1205
StandardsIEC/EN 60204-1, EN ISO 13849-1, BG-GS-ET-20
Compliance with the Directives (Y/N) Yes
Climatic stressEN 60068-2-3, BG-GS-ET-14
Mountingsnaps onto standard DIN rail to EN 60715
Terminal designationsIEC/EN 60947-1
Materials
- Material of the housingsPlastic, glass-fibre reinforced thermoplastic, ventilated
- Material of the contactsAg-Ni, 0,2 µm gold flashed
Weight195
Start input (Y/N)No
Feedback circuit (Y/N)No
Reset after disconnection of supply voltage (Y/N)Yes
Automatic reset function (Y/N)Yes
Reset with edge detection (Y/N)No

Mechanical data

Connection typeScrew connection
Cable section
- Min. Cable section0,2
- Max. Cable section2.5
Pre-wired cablerigid or flexible
Tightening torque for the terminals0,6
Detachable terminals (Y/N)No
Mechanical life20.000.000 operations
Electrical lifetime150.000 operations for 230 VAC, 5 A (cos φ = 1)
hysteresis10 % of standstill frequency
restistance to shock30 g / 11 ms
Resistance to vibration To EN 60068-2-610…55 HZ, Amplitude 0,35 mm
Standstill frequencyInputs X1 / X2: 2 / 2

Ambient conditions

Ambient temperature
- Min. environmental temperature0
- Max. environmental temperature+55
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+70
Protection class
- Protection class-EnclosureIP40
- Protection class-TerminalsIP20
- Protection class-ClearanceIP54
Air clearances and creepage distances To IEC/EN 60664-1
- Rated impulse withstand voltage Uimp4.8 kV
- Overvoltage categoryII To VDE 0110
- Degree of pollution3 To VDE 0110

Electromagnetic compatibility (EMC)

EMC rating10 V/m

Electrical data

Rated DC voltage for controls
- Max. rated DC voltage for controls20.4
- Max. rated DC voltage for controls27.6
Rated AC voltage for controls, 50 Hz
- Min. rated AC voltage for controls, 50 Hz-
- Max. rated AC voltage for controls, 50 Hz-
Rated AC voltage for controls, 60 Hz
- Min. rated AC voltage for controls, 60 Hz-
- Max. rated AC voltage for controls, 60 Hz-
Contact resistancemax. 100 mΩ
Power consumption<>
Type of actuationDC
Rated insulation voltage Ui250 V
Rated operating voltage Ue24 VDC ±15%
Thermal test current Ithe6 A
Operating current Ie0,2 A
Electronic protection (Y/N)No

Inputs

Monitored inputs
- Short-circuit recognition (Y/N)No
- Wire breakage detection (Y/N)Yes
- Earth connection detection (Y/N)Yes
Input frequency4000
min. pulse duration125
Input resistanceapprox. 4000 Ω at GND
Input signal "1"10 … 30 VDC
Input signal "0"0 … 2 VDC
Cable length100 m with 0,75 mm² (for Rated voltage)

Outputs

Stop category0
Number of safety contacts2
Number of auxiliary contacts0
Number of signalling outputs2
Switching capacity
- Switching capacity of the safety contactsmin. 10 mA, max. 6 A
- Switching capacity of the signaling/diagnostic outputsY1, Y2: max. 100 mA
Fuse rating
- Protection of the safety contacts6 A gG D-fuse
- Fuse rating for the signaling/diagnostic outputsshort-circuit proof
Signalling outputY1: Authorized operation, safety contacts on;
Y2: Error, high signal
Utilisation category To EN 60947-5-1AC-15: 230 V / 3 A
DC-13: 24 V / 2 A
Number of undelayed semi-conductor outputs with signaling function2
Number of undelayed outputs with signaling function (with contact)0
Number of delayed semi-conductor outputs with signaling function.0
Number of delayed outputs with signalling function (with contact).0
Number of secure undelayed semi-conductor outputs with signaling function0
Number of secure, undelayed outputs with signaling function, with contact.0
Number of secure, delayed semi-conductor outputs with signaling function0
Number of secure, delayed outputs with signaling function (with contact).0

LED switching conditions display

LED switching conditions display (Y/N)Yes
Number of LED´s1

Integral system diagnosis $missingShortName$

Integral system diagnosis ISD
- The following faults are registered by the safety monitoring modules and indicated by ISD
- Interruption of the connections to the inductive proximity switches
- Failure of the safety relay to pull-in or drop-out
- Fault on the input circuits or the relay control circuits of the safety monitoring module
- Failure of the proximity switches
- Failure of one channel being evaluated

Miscellaneous data

Applications safe standstill monitoring

Dimensions

Dimensions
- Width22.5 mm
- Height100 mm
- Depth121 mm

notice

Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

notice - Wiring example

To monitor one guard door at plants with dangerous run-on movements up to PL d and Category 3
Standstill monitoring for unlocking solenoid interlocks
The solenoid interlock can be opened, when the fail-safe standstill monitor has detected the end of the run-on movement by means of two inductive proximity switches. When the button (E) is actuated, the coil of the solenoid interlock is energised.
For suitable IFL range p-type inductive proximity switches, refer to "Schmersal Catalogue Automatisierungstechnik".
The wiring diagram is shown with guard doors closed and in de-energised condition.
The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 

8 (017) 255-8-000

Или отправьте нам запрос на e-mail:  zapros@filfar.by

 

Информация для заказа
  • Цена: Цену уточняйте
Контакты
  • Телефон:
    +375(44)765-55-50
    +375(29)690-11-55
  • Контактное лицо:
    Сергей, Владимир
  • Адрес:
    ул. Западная, д.13, каб.519, Минск, Беларусь
  • Email:
    zapros@filfar.by
Карта