Ordering details | |
---|---|
Product type description | AZM 161 B ST2-AS RA |
Article number | 101209102 |
EAN Code | 4030661405643 |
eCl@ss | 27-27-26-03 |
Approval | |
Approval | ![]() ![]() ![]() |
Classification | |
Standards | EN ISO 13849-1, IEC 61508 |
PL | up c |
Control category | 1 |
PFH | 1.14 x 10-6 / h |
- notice | up to max. 100.000 switching cycles/year |
SIL | up 1 |
Mission time | 20 Years |
If a fault exclusion for hazardous damage of the 1-channel mechanics is authorized and an adequate protection against tampering is ensured, suitable for use up to: | |
Standards | EN ISO 13849-1, IEC 61508 |
PL | up d |
Control category | 3 |
PFH value | 1.01 x 10-7 / h |
- notice | up to max. 100.000 switching cycles/year |
SIL | up 2 |
Mission time | 20 Years |
Global Properties | |
Permanent light | AZM 161 AS |
Standards | EN 50295, EN 60947-5-1, IEC 61508, EN ISO 13849-1 |
Compliance with the Directives (Y/N) ![]() | Yes |
Number of actuating directions | 3 |
Active principle | electromechanical |
Duty cycle ED | Magnet 100 % |
Materials | |
- Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Housing coating | None |
Weight | 450 |
Guard locking monitored (Y/N) | No |
Actuator monitored (Y/N) | Yes |
Response time | <> |
Mechanical data | |
Actuating play in direction of actuation | 5.5 |
Design of electrical connection | connector plug M12, 4-pole |
connector | right |
Mechanical life | > 1.000.000 operations |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 HZ … 150 HZ, Amplitude 0,35 mm |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | Yes |
Emergency release (Y/N) | No |
Latching force | 30 |
Clamping force F | 2000 N |
Max. Actuating speed | 2 |
Actuating frequency | max. 1000 / h |
Ambient conditions | |
Ambient temperature | |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +60 |
Storage and transport temperature | |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Relative humidity | 30 … 95 |
- non-condensing | |
Protection class | IP67 to IEC/EN 60529 |
Protection rating | II ![]() |
Air clearances and creepage distances To IEC/EN 60664-1 | |
- Rated impulse withstand voltage Uimp | 0,8 kV |
- Rated insulation voltage Ui | 32 VDC |
- Overvoltage category | III |
- Degree of pollution | 3 |
Electrical data | |
Power to unlock | No |
Power to lock | Yes |
Electrical data - AS interface | |
AS-i Supply voltage | 26.5 … 31.6 VDC, Protection against polarity reversal |
AS-i operating current | ≤ 250 |
AS-i Device insulation | internally short-circuit proof |
AS-i Specification | |
- version | V 2.1 |
- Profile | S-7.B.F.E |
- IO-Code | 0x7 |
- ID-Code | 0xB |
- ID-Code1 | 0xF |
- ID-Code2 | 0xE |
AS-i Inputs | |
- Channel 1 | Data bits DI 0/DI 1= dynamic code transmission |
- Channel 2 | Data bits DI 2/DI 3= dynamic code transmission |
AS-i Outputs | |
- DO 0 | Solenoid control |
- DO 1 | not used |
- DO 2 | not used |
- DO 3 | not used |
AS-i Parameter bits | |
- P0 | Actuator detected |
- P1 | Solenoid interlock locked |
- P2 | magnet voltage in tolerance range |
- P3 | error message - locking/unlocking of the solenoid interlock blocked |
AS-i input module address | 0 |
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device | |
LED switching conditions display | |
LED switching conditions display (Y/N) | Yes |
AS-i LED switching conditions display | |
(1) yellow LED | Channel 2 / AS-i SaW Bit 2,3 |
(2) green/red LED (AS-i duo LED) | Supply voltage / Communication error / slave address = 0 or periphery error |
(3) yellow LED | Channel 1 / AS-i SaW Bit 0,1 |
ATEX | |
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
Miscellaneous data | |
Applications | ![]() ![]() ![]() |
Dimensions | |
Dimensions of the sensor | |
- Width of sensor | 130 |
- Height of sensor | 90 |
- Length of sensor | 30 |
Pin assignment | |
1 | AS-i + |
2 | Aux − (P) |
3 | AS-i − |
4 | Aux + (P) |
notice | |
Interlocks with power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. | |
Manual release | |
• For maintenance, installation, etc. | |
• For manual release using M5 triangular key, available as accessory | |
Included in delivery | |
Actuators must be ordered separately. |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |
Или отправьте нам запрос на e-mail: zapros@filfar.by