OOO "ФилФар Технолоджи"

103007474 | SLC440AS-ER-0730-14

  103007474 | SLC440AS-ER-0730-14
Под заказТолько оптом

Цену уточняйте

  • +375 показать номер +375(44)765-55-50
  • +375(29)690-11-55

Заказ только по телефону

  • Контакты
    • Телефон:
      +375(44)765-55-50
      +375(29)690-11-55
    • Контактное лицо:
      Сергей, Владимир
    • Адрес:
      ул. Западная, д.13, каб.519, Минск, Беларусь
    • Email:
      zapros@filfar.by

Техническая спецификация в PDF  

Ordering details

Product type descriptionSLC440AS-ER-0730-14
Article number103007474
EAN Code
eCl@ss27-27-27-04

Approval

Approval


Classification

StandardsEN ISO 13849-1, EN 62061
PLe
Control category4
PFH value5.17 x 10-9 /
SILup 3
Mission time20 Years

Global Properties

Permanent lightSLC440AS Sicherheits-Lichtvorhang
StandardsEN 61496-1, CLC/TS 61496-2, EN ISO 13849, EN 62061, EN 50295
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N)Yes
Safety type in accordance with IEC 61496-14
Active principleoptoelectronic
Materials
- Material of the housingsAluminium
Weight1200
Beam coding (Y/N)No
Protection field height730
Range of the protection field300 - 7000
Reaction time≤ 23
Wave length of the sensors880
Fade-out is possible (Y/N)Yes

Mechanical data

Detection ability for test bodies14
Number of beams72
Design of electrical connectionConnector
- Wiring of the transmitterconnector plug M12, 4-pole
- Wiring of the receiverconnector plug M12, 5-pole
restistance to shock10 / 16
Resistance to vibration10 … 55 HZ, Amplitude 0,35 mm

Ambient conditions

Ambient temperature
- Min. environmental temperature−10
- Max. environmental temperature+50
Storage and transport temperature
- Min. Storage and transport temperature−25
- Max. Storage and transport temperature+70
Protection classIP67 to IEC/EN 60529
Protection ratingIII
Rated impulse withstand voltage0,8
Rated insulation voltage32
Overvoltage categoryIII
Degree of pollution2

Electrical data - AS interface

AS-i Supply voltage18.0 … 31.6 VDC, Protection against polarity reversal
AS-i operating current≤ 50 (Receiver)
AS-i Device insulationinternally short-circuit proof
AS-i SpecificationSafety Slave
- versionV 3.0
- ProfileS-0.B.F.E
AS-i Inputs
- Channel 1Data bits DI 0/DI 1= dynamic code transmission
- Channel 2Data bits DI 2/DI 3= dynamic code transmission
AS-i OutputsDO 0 … DO 3 not used
AS-i Parameter bits
- P0not used
- P1Low beam quality
- P2not used
- P3device error (FID)
AS-i input module address0
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device
noticeSet the parameter outputs to "1111" (0xF)
FID: periphery error

Electrical data - Auxiliary voltage (Aux)

Supply voltage24 (−15 / +10) stabilised PELV
Operating current Transmitter≤ 75
Operating current Receiver≤ 150
Device insulation≤ 4 A (if used in accordance with UL 508)

LED switching conditions display

LED switching conditions display (Y/N)Yes
- green/red LED (AS-i duo LED)Supply voltage / Communication error / slave address = 0 / periphery error detected
- Status and diagnosticsTransmitter + receiver
- 7-segment displayReceiver

ATEX

Explosion protection categories for gasesNone
Explosion protected category for dustsNone

Dimensions

Dimensions of the sensor
- Width of sensor27.8
- Height of sensor (Receiver)863
- Height of sensor (Transmitter)843
- Length of sensor33

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 