Ordering details | |
---|---|
Product type description | ASIM-C-M12-4P-2M |
Article number | 103004695 |
EAN Code | |
eCl@ss | 27-27-24-02 |
Approval | |
Approval | ![]() ![]() ![]() |
Classification | |
Standards | EN ISO 13849-1, EN 62061 |
PL | e |
Control category | 4 |
PFH value | No significant contribution |
PFD value | No significant contribution |
SIL | 3 |
Mission time | 20 Years |
Global Properties | |
Permanent light | ASIM-C-M12 |
Standards | EN 50295, EN 60204-1, EN ISO 13849-1, EN 62061 |
Compliance with the Directives (Y/N) ![]() | Yes |
Suitable for safety functions (Y/N) | Yes |
Materials | |
- Material of the housings | Thermoplastic PBT |
- Material of the cable | Polyurethane |
Weight | 260 |
Response time | <> |
Duration of risk | <> |
Mechanical data | |
Design of electrical connection | Socket, M12, 4-pole, A-coded |
Cable length | 2 |
restistance to shock | 30 / 11 |
Resistance to vibration | 10 … 57 HZ, Amplitude 0,75 mm |
Ambient conditions | |
Ambient temperature | |
- Min. environmental temperature | −20 |
- Max. environmental temperature | +60 |
Storage and transport temperature | |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +80 |
Relative humidity | 30 … 95 |
- non-condensing, non-icing | |
Protection class | IP67 to IEC/EN 60529 |
Protection rating | III |
Air clearances and creepage distances To IEC/EN 60664-1 | |
- Rated impulse withstand voltage | 0,8 |
- Rated insulation voltage | 32 |
- Overvoltage category | III |
- Degree of pollution | 3 |
Electrical data - AS interface | |
AS-i Supply voltage | 26.5 … 31.6 VDC, Protection against polarity reversal |
AS-i operating current | ≤ 90 |
AS-i Device insulation | internally short-circuit proof |
AS-i Specification | |
- version | V3.0 |
- Profile | S-0.B.F.0 |
AS-i Inputs | |
- Channel 1 | Data bits DI 0/DI 1= dynamic code transmission |
- Channel 2 | Data bits DI 2/DI 3= dynamic code transmission |
AS-i Outputs | |
- DO 0 | not used |
- DO 1 ... DO 3 | not used |
AS-i Parameter bits | |
- P0 | Communication monitoring |
- P1 ... P3 | not used |
AS-i input module address | 0 |
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device | |
notice | Set the parameter outputs to "1111" (0xF) |
LED switching conditions display | |
LED switching conditions display (Y/N) | Yes |
AS-i LED switching conditions display | |
(1) green LED | Supply voltage / slave address = 0 |
(2) red LED | Communication error / slave address = 0 |
(3) yellow LED | I1 = Status Safety input 1 |
(4) yellow LED | I2 = Status Safety input 2 |
(5) yellow LED | - |
Dimensions | |
Dimensions | |
- Width | 27.7 |
- Height | 40.5 |
- Depth | 22 |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |
Или отправьте нам запрос на e-mail: zapros@filfar.by