Ordering details | |
---|---|
Product type description | ZQ 900 FK-AS N |
Article number | ZQ 900 FK-AS N |
EAN Code | |
eCl@ss | 27-37-12-90 |
Approval | |
Approval | ![]() ![]() ![]() |
Classification | |
Standards | EN ISO 13849-1, IEC 61508 |
PL | up e |
Control category | up 4 |
PFH value | ≤ 1.4 x 10− 8 /h |
- notice | up to max. 5.000 switching cycles/year |
SIL | up 3 |
Mission time | 20 Years |
Global Properties | |
Permanent light | ZQ 900 AS |
Standards | EN 60947-5-1, EN ISO 13850, EN 50295, EN ISO 13849-1, IEC 61508 |
Compliance with the Directives (Y/N) ![]() | Yes |
Materials | |
- Material of the housings | zinc die-cast, painted |
- Material of the cover | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Housing coating | painted |
Weight | |
Response time | <> |
Emergency-Stop button (Y/N) | Yes |
Mechanical data | |
Design of electrical connection | Connection for flat cable |
Mechanical life | > 100.000 operations |
Switching frequency | max. 1/s |
Actuating force | max. 200 N |
actuating travel | max. 400 mm |
restistance to shock | 15 g / 11 ms |
Resistance to vibration | 10 … 150 HZ, Amplitude 0,35 mm / 5 g |
Length of wire | max. 50 m |
Ambient conditions | |
Ambient temperature | |
- Min. environmental temperature | −25 |
- Max. environmental temperature | + 60 |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Relative humidity | 30 … 95 |
- non-condensing | |
- non-icing | |
Protection type IP | IP65, IP67 |
Air clearances and creepage distances To IEC/EN 60664-1 | |
- Rated impulse withstand voltage Uimp | 800 V |
- Rated insulation voltage Ui | 32 V |
- Overvoltage category | III |
- Degree of pollution | 3 |
Electrical data | |
Switching principle | Snap switch element |
positive break NC contact ![]() | |
positive break NC contact ![]() | |
Electrical data - AS interface | |
AS-i Supply voltage | 18 … 31.6 VDC, Protection against polarity reversal |
- Min. supply voltage | 18 |
- Max. supply voltage | 31.6 |
AS-i operating current | ≤ 50 |
AS-i Device insulation | internally short-circuit proof |
AS-i Specification | |
- version | V 3.0 |
- Profile | S-0.B.F.F |
- IO-Code | 0x0 |
- ID-Code | 0xB |
- ID-Code1 | 0xF |
- ID-Code2 | 0xF |
AS-i Inputs | |
- Channel 1 | Data bits DI 0/DI 1= dynamic code transmission |
- Channel 2 | Data bits DI 2/DI 3= dynamic code transmission |
AS-i Outputs | DO 0 … DO 3 not used |
AS-i Parameter bits | |
- P0 | Channel 2 switched |
- P1 | not used |
- P2 | not used |
- P3 | not used |
AS-i input module address | 0 |
- Default on address 0, programmable via the AS-Interface Master or Hand-held programming device | |
LED switching conditions display | |
LED switching conditions display (Y/N) | No |
Dimensions | |
Dimensions of the sensor | |
- Width of sensor | 71.5 |
- Height of sensor | 220.3 mm up 236 mm |
- Length of sensor | 97 |
notice | |
At 5 m distance intermediate wire supports are required, see accessories | |
Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. | |
As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. | |
The addressing must take place via the M12 connector or the flat cable connection. |