123371 | CTP-L2-AP-M-HA-AZ-SH-123371

Описание
Информация для заказа
Mechanical values and environment | |
|---|---|
| Housing material | |
| Switch head cover | Die-cast zinc |
| Safety switch housing | Fiber glass reinforced thermoplastic |
| Weight | |
| Net | 0,42 kg |
| Ambient temperature | |
| At UB = 24V DC | -20 ... +55 °C |
| Degree of protection | IP67 Screwed tight plug connector/mating component |
| Resilience to vibration | In acc. with EN IEC 60947-5-3 |
| Mechanical life | 1 x 106 |
| Installation position | Any |
| Ready delay | max.1 s |
| Switching frequency | max.0,5 Hz |
| Connection | 1 plug connector M23, 19-pin, RC18 |
| Approach speed | 20 m/min |
| Guard locking principle | Open-circuit current principle |
| Locking force Fmax | 3900 N |
| Locking force FZh | 3000 N Fzh = Fmax/1.3 Depending on the actuator used |
| Retention force | 20 N |
| Extraction force | 20 N |
| Actuating force | 10 N |
| Overtravel | 5 mm |
Electrical connection ratings | |
| Test-pulse interval | min.100 ms |
| Test pulses | max.0,3 ms Applies for a load with C ? 30nF and R ? 20kOhm |
| Operating voltage DC | |
| UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%,="" pelv=""> |
| Current consumption | |
| IUB | 40 mA |
| IIMP | 400 mA |
| Utilization category according to EN 60947-5-2 | |
| DC-13 | 24V 150mA Caution: outputs must be protected with a free-wheeling diode in case of inductive loads |
| Solenoid operating voltage DC | |
| UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%,="" pelv=""> |
| Fusing | |
| External (operating voltage UB) | 0,25 ... 2 A |
| External (solenoid operating voltage IMP) | 0,5 ... 8 A |
| Rated insulation voltage Ui | max.50 V |
| Rated impulse withstand voltage Uimp | max.0,5 kV |
| Power consumption | 6 W |
| EMC protection requirements | In acc. with EN IEC 60947-5-3 |
| Solenoid duty cycle | 100 % |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Safety class | |
| EN IEC 61140 | III |
| Switching load | |
| According to UL | 24V DC, class 2 Alternatively see operating instructions |
| Safety outputs FO1A / FO1B | |
| Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
| Switching current | |
| Per safety output FO1A / FO1B | 1 ... 150 mA |
| Output voltage | |
| High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
| Low U(FO1A) / U(FO1B) | |
- Цена: Цену уточняйте
Информация для покупателя
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |


Mechanical values and environment