Продавец OOO "ФилФар Технолоджи" развивает свой бизнес на Deal.by 9 лет.
Знак PRO означает, что продавец пользуется одним из платных пакетов услуг Deal.by с расширенными функциональными возможностями.
Сравнить возможности действующих пакетов
Начать продавать на Deal.by 18 отзывов
+375 (44) 765-55-50
+375 (29) 690-11-55
OOO "ФилФар Технолоджи"

124468 | CTP-L1-AP-U-HA-AZ-SII-124468

124468 | CTP-L1-AP-U-HA-AZ-SII-124468, фото 2
Описание
Информация для заказа

Техническая спецификация в PDF  

Mechanical values and environment

Housing material
Switch head coverDie-cast zinc
Safety switch housingFiber glass reinforced thermoplastic
Weight
Net 0,42 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protectionIP67 / IP69 / IP69K Screwed tight plug connector/mating component
Resilience to vibrationIn acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation positionAny
Ready delaymax.1 s
Switching frequencymax.0,5 Hz
Connection2 plug connectors M12, 5-pin + pin 5 not used
Approach speed 20 m/min
Guard locking principleClosed-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N  Fzh = Fmax/1.3 Depending on the actuator used
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm

Electrical connection ratings

Test-pulse intervalmin.100 ms
Test pulsesmax.0,3 ms  Applies for a load with C ? 30nF and R ? 20kOhm
Operating voltage DC
UUB 24 V DC  -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%,="" pelv="">
Current consumption
IUB 40 mA
IIMP 400 mA
Utilization category according to EN 60947-5-2
DC-1324V 150mA Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
Solenoid operating voltage DC
UIMP 24 V DC  -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%,="" pelv="">
Fusing
External (operating voltage UB) 0,25 ... 2 A
External (solenoid operating voltage IMP) 0,5 ... 8 A
Rated insulation voltage Uimax.50 V
Rated impulse withstand voltage Uimpmax.0,5 kV
Power consumption 6 W
EMC protection requirementsIn acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1)3
Safety class
EN IEC 61140III
Switching load
According to UL24V DC, class 2 Alternatively see operating instructions
Safety outputs FO1A / FO1B
Type of output2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
LOW U(FO1A) / U(FO1B)
  • Цена: Цену уточняйте
Информация для покупателя

ООО «ФилФар Технолоджи»

220036, г. Минск, ул. Западная, д.13, к.519

Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015

Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь

УНП: 192123248

Регистрационный орган: Минский горисполком

Дата регистрации компании: 18.09.2013

Ссылка на свидетельство/лицензию

Режим работы:

ДеньВремя работы
Понедельник09:00-17:00
Вторник09:00-17:00
Среда09:00-17:00
Четверг09:00-17:00
Пятница09:00-17:00
СубботаВыходной
ВоскресеньеВыходной