Mechanical values and environment

Housing material
Switch head coverDie-cast zinc
Safety switch housingFiber glass reinforced thermoplastic
Weight
Net 0,42 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protectionIP67 / IP69 / IP69K Screwed tight plug connector/mating component
Resilience to vibrationIn acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation positionAny
Ready delaymax.1 s
Switching frequencymax.0,5 Hz
Connection1 plug connector M12, 8-pin
Approach speed 20 m/min
Guard locking principleClosed-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N  Fzh = Fmax/1.3 Depending on the actuator used
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm

Electrical connection ratings

Test-pulse intervalmin.100 ms
Test pulsesmax.0,3 ms  Applies for a load with C ? 30nF and R ? 20kOhm
Operating voltage DC
UUB 24 V DC  -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%,="" pelv="">
Current consumption
IUB 40 mA
IIMP 400 mA
Utilization category according to EN 60947-5-2
DC-1324V 150mA Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
Solenoid operating voltage DC
UIMP 24 V DC  -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%,="" pelv="">
Fusing
External (operating voltage UB) 0,25 ... 2 A
External (solenoid operating voltage IMP) 0,5 ... 8 A
Rated insulation voltage Uimax.50 V
Rated impulse withstand voltage Uimpmax.0,5 kV
Power consumption 6 W
EMC protection requirementsIn acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1)3
Safety class
EN IEC 61140III
Switching load
According to UL24V DC, class 2 Alternatively see operating instructions
Safety outputs FO1A / FO1B
Type of output2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Off-state current Irmax.0,25 mA
Switch-on timemax.400 ms
Discrepancy time
Both safety outputsIn acc. with EN IEC 60947-5-3max.10 ms
Monitoring output OD
Type of outputp-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OI
Type of outputp-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC

Operating distance

Repeat accuracy R
According to EN 60947-5-2 10 %

Miscellaneous

For the approval according to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

Reliability values acc. to EN ISO 13849-1

Performance LevelPL e
Category 4
PFHD4.1 x 10 -9
Mission time 20 y

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 

8 (017) 255-8-000

Или отправьте нам запрос на e-mail:  zapros@filfar.by

 

Информация для заказа
  • Цена: Цену уточняйте
Контакты
  • Телефон:
    +375(44)765-55-50
    +375(29)690-11-55
  • Контактное лицо:
    Сергей, Владимир
  • Адрес:
    ул. Западная, д.13, каб.519, Минск, Беларусь
  • Email:
    zapros@filfar.by
Карта