Mechanical values and environment

Housing material
SlideStainless steel
Safety switch housingDie-cast aluminum
Weight
Net 1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protectionIP67 Screwed tight plug connector/mating component
Mechanical life 1 x 106
Installation positionAny Preferably head downward
Degree of freedom
X±5 mm
Y±5 mm
Z±4 mm
Ready delay 10 s
Switching frequencymax.0,5 Hz
Connection2 plug connectors M12, 5 and 8-pin
Approach speed 20 m/min
Guard locking principleClosed-circuit current principle
Locking force Fmax 6500 N
Locking force FZh 5000 N

Electrical connection ratings

Operating voltage DC
UB 24 V DC  -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%,="" pelv="">
LED1, LED2 24 V DC  -15% ... 10%
Current consumption
IB 80 mA
ICM 480 mA
Utilization category according to EN 60947-5-2
DC-1324V 200mA Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
Solenoid operating voltage DC
UCM 24 V DC  -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%,="" pelv="">
Fusing
External (operating voltage UB) 0,25 ... 2 A
External (operating voltage UCM) 0,5 ... 8 A
Power consumption
Solenoidmax.12 W
EMC protection requirementsIn acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1)3
Safety class
EN IEC 61140III
Switching load
According to UL24V DC, class 2 For alternatives see operating instructions
Safety outputs OA/OB
Type of outputSemiconductor outputs, p-switching, short circuit-proof
Output voltage
High U(OA,OB) UB-1,5V ... UB V DC  Values at a switching current of 50mA without taking into account the cable lengths
Low U(OA,OB) 0 ... 1 V DC
Output current
per safety output 1 ... 200 mA
Off-state current Irmax.0,25 mA
Risk time according to EN 60947-5-3
Single devicemax.400 ms
Delay per device 5 ms
Switch-on time
Safety outputs 400 ms
Discrepancy time
Both safety outputsmax.10 ms
Feedback loop Y
Input voltage
High 15 ... 27,6 V DC
Low 0 ... 1 V DC
Monitoring output OUT
Type of outputSemiconductor output, p-switching, short circuit-proof
Output voltage
OUT 0,8xUB ... UB V DC
Output current
OUT 1 ... 50 mA

Operating distance

Repeat accuracy R
According to EN 60947-5-2 10 %

Miscellaneous

For the approval according to UL the following appliesOperation only with UL class 2 power supply, or equivalent measures see operating instructions

Reliability values acc. to EN ISO 13849-1

Monitoring of guard locking and the safety guard position
Category
Head upward 3
Head downward or horizontal 4
Performance LevelPL e
PFHD
Head upward4.29 x 10-8
Head downward or horizontal3.1 x 10-9
Control of the guard locking
CategoryDepending on external control of guard locking Feedback loop and LEDs have the same ground potential as the guard locking solenoid
Performance LevelDepending on external control of guard locking Feedback loop and LEDs have the same ground potential as the guard locking solenoid
PFHDDepending on external control of guard locking Feedback loop and LEDs have the same ground potential as the guard locking solenoid

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

 