Продавец OOO "ФилФар Технолоджи" развивает свой бизнес на Deal.by 12 лет.
Знак PRO означает, что продавец пользуется одним из платных пакетов услуг Deal.by с расширенными функциональными возможностями.
Сравнить возможности действующих пакетов
Начать продавать на Deal.by 18 отзывов
+375 (44) 765-55-50
+375 (29) 690-11-55
6667 тестовая компания

098225 | CES-AR-AES-12

098225 | CES-AR-AES-12, фото 2
Описание
Информация для заказа

Техническая спецификация в PDF  

Mechanical values and environment

Dimensions114 x 99 x 45
Housing materialPlastic PA6.6
Weight
Net 0,25 kg
Ambient temperature
At UB = DC 24 V -20 ... 55 °C
Atmospheric humidity
Not condensingmax.80 % rH
Degree of protectionIP20
Resilience to vibrationIn acc. with EN 60947-5-2
Mounting methodMounting rail 35 mm according to EN 60715
Ready delaymax.8 s  After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.
ConnectionPlug-in screw terminals coded
Number of LED displays 3
O1 ... O12
Number of monitoring outputs 12
Start button S
Manual start operating mode
Duration of operation of start buttonmin.250 ms
Response delay start button300 ... 600 ms
13/14, 23/24, 33/34, 43/44
Number of safety contacts 4 Relays with internally monitored contacts
Mechanical life
Relay 10 x 106
Switching frequency 1 Hz  If the current load is > 100 mA, a switching frequency of 0.1 Hz should not be exceeded as this will affect the mechanical life of the relay contacts.

Electrical connection ratings

Operating voltage DC
UB24 -10% ... 10% V DC  Regulated, residual ripple < 5="" %="">
Current consumption
IB (with relay energized) 1200 mA  Taking into account the load currents at the monitoring outputs (20 mA each)
Fusing
External (operating voltage UB)2,5 ... 8 A
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4 kV
EMC protection requirementsIn acc. with EN 60947-5-3
Degree of contamination (external, according to EN 60947-1)2
Connection cross-section 0,14 ... 2,5 mm?
Switching delay from state changemax.480 ms  Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-Или отправьте нам запрос наtputs following removal of the actuator.
STATE
LED indicator
STATEGreen LED: Status of the device
OUT
LED indicator
OUTYellow LED: State of the AR chain
DIA
LED indicator
DIARed LED: Fault display
O1 ... O12
Type of outputSemiconductor outputs, p-switching, short circuit-proof
Output voltage
High UB - 20% ... UB V DC
LOW 0 ... 1 V DC
Output currentmax.20 mA
DIA
Type of outputSemiconductor output, p-switching, short circuit-proof
  • Цена: Цену уточняйте
Информация для покупателя

ООО «ФилФар Технолоджи»

220036, г. Минск, ул. Западная, д.13, к.519

Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015

Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь

УНП: 192123248

Регистрационный орган: Минский горисполком

Дата регистрации компании: 18.09.2013

Ссылка на свидетельство/лицензию

Режим работы:

ДеньВремя работы
Понедельник09:00-17:00
Вторник09:00-17:00
Среда09:00-17:00
Четверг09:00-17:00
Пятница09:00-17:00
СубботаВыходной
ВоскресеньеВыходной