Mechanical values and environment

Housing materialPlastic PA6.6
Weight
Net 0,2 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Atmospheric humidity
Not condensingmax.80 % rH
Degree of protectionIP20
Mounting methodMounting rail 35mm according to DIN EN 60715 TH35
Mounting distance
Sideways toward the neighboring devicemin.10 mm  If several evaluation units are mounted side by side in a control cabinet without air circulation (e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. The distance enables heat from the evaluation unit to dissipate.
Number of read heads1 read head can be connected
Ready delay10 ... 12 s  After the operating voltage is switched on, the relay outputs are switched off and the door monitoring output is set LOW during the ready delay. For the visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.
Reaction time
After change in the actuation statusmax.210 ms  Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-Или отправьте нам запрос наtputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the switch-off delay can increase to max. 250 ms. After a brief actuation < 0.25="" s,="" the="" switch-on="" delay="" can="" increase="" to="" max.="" 3="" s="" if="" this="" is="" followed="" immediately="" by="" further="">
Duration of operation start button (for Manual start operating mode)min.250 ms
Response delay start button (for Manual start operating mode)200 ... 300 ms
Switching frequencymax.0,25 Hz  In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed
Dwell timemin.3 s  The dwell time is the time that the actuator must be inside or outside the operating distance.
ConnectionPlug-in connection terminals, coded Terminals not included
Safety contacts 13/14, 23/24
Number of safety contacts 2 Relays with internally monitored contacts
Mechanical life
Operating cycles (relay) 10 x 106

Electrical connection ratings

Operating voltage DC
UB 21 ... 24 ... 27 V DC
Current consumption
(with relay energized) 150 mA  Without taking into account the load currents on the monitoring outputs
Fusing
External (operating voltage UB) 0,4 ... 8 A
EMC protection requirementsIn acc. with EN 60947-5-3
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section
(plug-in screw- / springterminals) 0,25 ... 2,5 mm?
Current via feedback loop 5 ... 8 ... 10 mA
permissible resistance in feedback loopmax.600 ?
Safety contacts 13/14, 23/24
Type of outputRelay contacts, floating
Switching current
At switching voltage AC/DC 21 ... 60 V 1 ... 300 mA
At switching voltage AC/DC 5 ... 30 V 10 ... 6000 mA
At switching voltage AC 5 ... 230 V 10 ... 2000 mA
Fusing
External (safety circuit) according to EN 60269-16 AgG or 6 A circuit breaker (characteristic B or C)
  • Цена: Цену уточняйте
Информация для покупателя

ООО «ФилФар Технолоджи»

220036, г. Минск, ул. Западная, д.13, к.519

Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015

Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь

УНП: 192123248

Регистрационный орган: Минский горисполком

Дата регистрации компании: 18.09.2013

Ссылка на свидетельство/лицензию

Режим работы:

ДеньВремя работы
Понедельник09:00-17:00
Вторник09:00-17:00
Среда09:00-17:00
Четверг09:00-17:00
Пятница09:00-17:00
СубботаВыходной
ВоскресеньеВыходной