085610 | ESM-BA201

Описание
Информация для заказа
Mechanical values and environment | |
|---|---|
| Housing material | Polyamide PA6.6 |
| Weight | |
| Net | 0,23 kg |
| Ambient temperature | |
| At UB = 24V DC | -15 ... 60 °C at 20% undervoltage Tmax: 50°C |
| At UB = 24V AC | -15 ... 40 °C |
| Degree of protection | IP20 |
| Mechanical life | |
| operating cycles | 10 x 106 |
| Contact material | AgSnO2 |
| Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
| Connection | Connection terminals |
| Length of control cable | |
| With conductor cross-section 0.75mm2 | 1000 m |
| Safety contacts 13/14, 23/24 | |
| Number of safety contacts | 2 |
Electrical connection ratings | |
| Operating voltage | |
| AC/DC | 24 V -10% ... +10% All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures. |
| Rated insulation voltage Ui | 250 V |
| Rated impulse withstand voltage Uimp | |
| Leakage path/air gaps | 4 kV |
| Overvoltage category according to IEC EN 60664-1 | 3 |
| Reverse polarity protection | |
| On version UB =24V DC | |
| Power consumption | |
| at 24V DC | 1,5 W |
| Degree of contamination (external, according to EN 60947-1) | 2 |
| Connection cross-section | 0,14 ... 2,5 mm? |
| Test voltage | |
| Control system/contacts | 2,5 kV |
| Control voltage | |
| On S11 | 18,6 ... 24 V 26 V Start button |
| Control current | |
| S11...S14 | 40 mA |
| LED indicator | 2 status displays (green) for relays K1 and K2 |
| Safety contacts 13/14, 23/24 | |
| Type of output | |
| NO | Relay contacts, floating and positively driven (redundant) Positively driven relay according to EN 50205 |
| Switching voltage | |
| AC | max.250 V |
| DC | max.24 V |
| Switching current | at 24Vmin.20 mA |
| Fusing | |
| External contact fuses (safety circuit) according to IEC 60269-1 | 10A gG (T6A / F8A) |
| Utilization category according to EN 60947-5-1 | |
| AC-15 | 3A, 250V |
| DC-13 | 3A, 24V |
| AC-12 | 6A ohmic load, 250V |
| DC-12 | 6A ohmic load, 24V |
| Breaking capacity according to UL | 6A 250V AC / 2A 24V DC |
Miscellaneous | |
| in compliance with | EN 60439-1: 1999 + A1: 2004{} EN 60947-1: 2007{} EN 60947-5-1: 2004{} EN 60947-7-1: 2002{} EN 61000-6-2: 2005{} EN 61000-6-3: 2007{} EN ISO 13849-1: 2015{} EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015{} EN 60204-1: 2007 |
Reliability values acc. to EN ISO 13849-1 | |
| Performance Level | PL e This value is dependent on the number of switching cycles and the switching current. |
- Цена: Цену уточняйте
Информация для покупателя
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |


Mechanical values and environment