Mechanical values and environment | |
|---|---|
| Housing material | Reinforced plastic{} die-cast zinc nickel-plated, stainless steel |
| Weight | |
| Net | 0,75 kg |
| Ambient temperature | |
| At UB = 24V DC | -20 ... 55 °C |
| Degree of protection | IP42 |
| Mechanical life | |
| 1 x 106 | |
| In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
| Installation position | Door hinge DIN right |
| Switching frequency | 0,25 Hz |
| Connection | Plug connector RC18 X6 |
| Guard locking principle | Open-circuit current principle |
| Locking force FZh | 2000 N |
Electrical connection ratings | |
| Utilization category according to EN 60947-5-2 | |
| DC-13 | 24V 200mA Caution: outputs must be protected with a free-wheeling diode in case of inductive loads. |
| Rated insulation voltage Ui | 30 V |
| Rated impulse withstand voltage Uimp | 1,5 kV |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Safety class | III |
| Discrepancy time | |
| Between FO1A and FO1B | max.10 ms |
| Risk time according to EN 60947-5-3 | max.350 ms |
| Transponder coding | Unicode |
| Power supply UB | |
| Operating voltage DC | |
| UB | 24 V DC -15% ... 10% (Reverse polarity protected, regulated, residual ripple <5%,> |
| Current consumption | |
| IUB | max.80 mA (no load on outputs) |
| Power supply UA | |
| Operating voltage DC | |
| UA | 24 V DC -15% ... 10% (Reverse polarity protected, regulated, residual ripple <5%,> |
| Current consumption | |
| IUA | max.375 mA (With energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V) |
| Safety outputs FO1A, FO1B | |
| Test pulses | max.0,3 ms |
| Test-pulse interval | min.100 ms |
| Type of output | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| UFO1A /UFO1B HIGH | UB-2V ... UB V DC Value at a switching current of 50mA without taking into account the cable lengths |
| UFO1A /UFO1B LOW | 0 ... 1 V DC |
| Output current | |
| Per safety output FO1A / FO1B | 1 ... 200 mA |
| Monitoring outputs OD, OT, OL, OI | |
| Type of output | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | UA-2V ... UA V DC Value at a switching current of 50mA without taking into account the cable lengths |
| Output current | max.50 mA |
| Controls and indicators | |
| Switching voltage | UA V |
| Switching current | 1 ... 10 mA |
| Breaking capacity | ma |
- Цена: Цену уточняйте
Информация для покупателя
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |


Mechanical values and environment