099182 | CMS-E-ER

Описание
Информация для заказа
Mechanical values and environment | |
|---|---|
| Housing material | Polyamide PA6.6 |
| Weight | |
| Net | 0,22 kg |
| Ambient temperature | 0 ... 55 °C |
| Degree of protection | Terminals IP20 / housing IP40 |
| Mechanical life | 10 x 106 |
| Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
| Connection | Connection terminals |
| Safety contacts 13/14 and 23/24 | |
| Number of safety contacts | 2 |
| Auxiliary contacts 31/32 | |
| Number of auxiliary contacts | 1 |
Electrical connection ratings | |
| Operating voltage | |
| AC/DC | -10% ... 24 V +10% V All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures. |
| Fusing | |
| Protection internal (operating voltage UB) | 0,75 A Automatically resetting fuse PTC |
| Rated insulation voltage Ui | |
| AC | 250 V |
| Degree of contamination (external, according to EN 60947-1) | 2 |
| Connection cross-section | 0,14 ... 2,5 mm? |
| LED indicator | 1 indicator LED Power (UB) and 2 status indicators for the read heads (K1/K2) |
| Safety contacts 13/14 and 23/24 | |
| Type of output | Relay contacts, floating 2 NO contact pairs |
| Current consumption | |
| at DC 24V | 10 ... 110 mA |
| Switching voltage | max.240 V |
| Switching current | |
| at DC 24V | 10 ... 3000 mA |
| Fusing | |
| External contact fuse (safety circuit) acc. to EN IEC 60269-1 | 4A gG |
| Utilization category according to EN 60947-4-1 | |
| AC-1 | 3A, 230V {} 3A, 24V Max. switching current per contact |
| Utilization category according to EN 60947-5-1 | |
| AC-15 | 0.9A , 240V and 0.9A , 24V Max. switching current per contact |
| DC-13 | 1.5A , 24V Max. switching current per contact |
| Switching load | |
| According to UL class 2 | Input: 24V AC/DC {} output: 30V AC, 24V DC |
| Breaking capacity (VA) | max.720 VA |
| Risk time according to EN 60947-5-3 | 20 ms |
| Auxiliary contacts 31/32 | |
| Type of output | Relay contacts, floating 1 NC contact pair |
| Switching current | |
| at DC 24V | max.1500 mA |
Miscellaneous | |
| in compliance with | EN ISO 13849-1: 2015{} EN ISO 13849-2:2012{} EN 50178: 1997{} EN 60204-1: 2006/Или отправьте нам запрос на15{} EN 14119:2013{} EN 6100-6-2: 2005{} EN 6100-6-3: 2007/A1: 2011{} EN 60947-5-3: 2013 |
Reliability values acc. to EN ISO 13849-1 | |
| Monitoring of the safety guard position | |
| Category | |
| With one read head | 4 This value is dependent on the number of switching cycles and the switching current. |
| With more than one read head | 3 This value is dependent on the number of switching cycles and the switching current. |
| Performance Level | |
| With one read head | |
- Цена: Цену уточняйте
Информация для покупателя
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |


Mechanical values and environment