077910 | CIA3SX1R1G08

Mechanical values and environment | |
|---|---|
| Housing material | PA 6.6 |
| Ambient temperature | 0 ... 55 °C |
| Degree of protection | IP20 |
| Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
| Number of read heads | max.1 |
| Connection | Plug-in screw terminals |
| Cable length | |
| RS232max.5 m | |
| RS422max.1000 m | |
Electrical connection ratings | |
| Operating voltage DC | 20 ... 24 ... 28 V DC All the electrical connections must either be isolated from the mains supply by a safety transformer according to IEC/EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures. |
| Current consumption | max.100 mA 65 mA |
| LED indicator | |
| Green | STATE LED operational |
| Yellow | ACTIVE LED data carrier active |
| Connection cross-section | 0,14 ... 2,5 mm? |
Interface, bus | |
| Data protocol | 3964R via RS232/RS422 |
| Data rate | 9600 kbit/s 28800 kbit/s Can be selected via DIP switches |
Miscellaneous | |
| Additional feature | |
| Moisture test (not condensing) at +50°C and 80% rel. h | |
| Vibration - IEC60068-2-6 amplitude 1mm, 10-55Hz, 3 axes | |
| Shock - IEC60068-2-27 acceleration 30g, 6 shocks per axis, 11ms/half sinewave | |
in combination withRead head CIT3ASX1N12STandData carrier CIS3AP10D05KH01K, CIS3AP10D05KH01K-P | |
| Read distance | |
| With center offset m=0 | 0 ... 3 ... 6,5 mm These values apply for the surface installation of the read head and the data carrier. |
| With center offset m=0 | 0 ... 3 ... 6 mm These values apply for the surface installation of the read head and flush installation of the data carrier in iron. |
| With center offset m=0 | 0 ... 3 ... 5 mm These values apply for the surface installation of the read head and flush installation of the data carrier in aluminum. |
| Center offset | |
| Read distance s = 3 mm | max.2,5 mm These values apply for the surface installation of the read head and the data carrier. |
| Write distance s = 3 mm | max.2 mm These values apply for the surface installation of the read head and the data carrier. |
| Write distance | |
| With center offset m=0 | 0 ... 3 ... 6 mm These values apply for the surface installation of the read head and the data carrier. |
| With center offset m=0 | 0 ... 3 ... 5,5 mm These values apply for the surface installation of the read head and flush installation of the data carrier in iron. |
| With center offset m=0 | 0 ... 3 ... 4,5 mm These values apply for the surface installation of the read head and flush installation of the data carrier in aluminum. |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013