10260076 | CombiPress PFMH





Описание
Информация для заказа
Performance characteristics | |
|---|---|
| Measuring range | -1 … 68 bar |
| Min. measuring span | 0.05 bar |
| Max. measuring span | 69 bar |
| Pressure type | 69 bar Absolute Relative (gauged) |
| Standard error of measurement (BFSL) | 69 bar Absolute Relative (gauged)± 0.04 % FSR , up to 2:1 turndown ratio ± 0.1 % FSR , up to 4:1 turndown ratio Including non-linearity, hysteresis and non-repeatability according BFSL For turndown, multiply this value by the applied turndown ratio |
| Max. measuring error | 69 bar Absolute Relative (gauged)± 0.04 % FSR , up to 2:1 turndown ratio ± 0.1 % FSR , up to 4:1 turndown ratio Including non-linearity, hysteresis and non-repeatability according BFSL For turndown, multiply this value by the applied turndown ratio± 0.1 % FSR , up to 2:1 turndown ratio ± 0.25 % FSR , up to 4:1 turndown ratio Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2) For turndown, multiply this value by the applied turndown ratio |
| Temperature coefficient | 69 bar Absolute Relative (gauged)± 0.04 % FSR , up to 2:1 turndown ratio ± 0.1 % FSR , up to 4:1 turndown ratio Including non-linearity, hysteresis and non-repeatability according BFSL For turndown, multiply this value by the applied turndown ratio± 0.1 % FSR , up to 2:1 turndown ratio ± 0.25 % FSR , up to 4:1 turndown ratio Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2) For turndown, multiply this value by the applied turndown ratio≤ 0.05 % FSR/10 K , measuring span ≤ 0.05 % FSR/10 K , zero point |
| Compensated temperature range | -40 … 85 °C |
| Long term stability | ≤ 0.1 % FSR/a , IEC 770 6.3.2 |
| Max. turndown ratio | 10 : 1 |
| Rise time (10 ... 90 %) | ≤ 0.3 s |
| Sample time | ≤ 0.3 s |
| Power-up time | < 10 s |
Compliance and approvals | |
| Explosion protection | < 10 sATEX II 1D Ex ia IIIC T100 °C Da ATEX II 1G Ex ia IIC T5 ATEX II 3G Ex nA II T5 |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |
Или отправьте нам запрос на e-mail: zapros@filfar.by
- Цена: Цену уточняйте
Информация для покупателя
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |




Performance characteristics