AX8206 | Axis modules 2-channel

Описание
Характеристики
Информация для заказа
| Technical data | AX8206-0000-0000 | AX8206-0100-0000 |
|---|---|---|
| Function | axis module | axis module with TwinSAFE Logic |
| Number of channels | 2 | |
| TwinSAFE safe drive technology | – | STO/SS1 |
| Feedback system | OCT | |
| Rated output current (axis) | 2 x 6 A | |
| Current control | 1 µs update time, 16 µs cycle time | |
| Minimum rated output current (channel) at full current resolution | 1 A | |
| Max. configurable rated output current | 8 A (right channel (B)) | |
| Peak output current (axis) | 14 A | 20 A | |
| DC-Link voltage | max. 875 V DC | |
| DC-Link capacitance | 135 µF | |
| Power loss | 23 W | |
| System bus | EtherCAT | |
| Drive profile | CiA402 according to IEC 61800-7-201 (CoE) | |
| Design form | modular system with 60 mm wide elements | |
| Protection class | IP 20 | |
| Ambient temperature (operation) | 0…+55 °C (see documentation) | |
| Approvals/markings | CE, cULus | |
| Realisation STO | by local TwinSAFE Logic, via FSoE or hard-wired via safe inputs | |
| Safety standard | EN ISO 13849-1:2015 (Cat 4, PL e), EN 61508:2010 (SIL 3) and EN 62061:2005 + A1:2013/A2:2015 (SIL CL3) | |
| Technical data | AX8206-0110-0000 | AX8206-0200-0000 |
|---|---|---|
| Function | axis module with TwinSAFE Logic and multi-feedback interface | axis module with TwinSAFE Logic |
| Number of channels | 2 | |
| TwinSAFE safe drive technology | STO/SS1 | Safe Motion |
| Feedback system | OCT, BiSS C, EnDat 2.2 | OCT |
| Rated output current (axis) | 2 x 6 A | |
| Current control | 1 µs update time, 16 µs cycle time | |
| Minimum rated output current (channel) at full current resolution | 1 A | |
| Max. configurable rated output current | 8 A (right channel (B)) | |
| Peak output current (axis) | 14 A | 20 A | |
| DC-Link voltage | max. 875 V DC | |
| DC-Link capacitance | 135 µF | |
| Power loss | 23 W | |
| System bus | EtherCAT | |
| Drive profile | CiA402 according to IEC 61800-7-201 (CoE) | |
| Design form | modular system with 60 mm wide elements | |
| Protection class | IP 20 | |
| Ambient temperature (operation) | 0…+55 °C (see documentation) | |
| Approvals/markings | CE, cULus | CE, cULus in preparation |
| Realisation STO | by local TwinSAFE Logic, via FSoE or hard-wired via safe inputs | |
| Safe stop functions | Safe Torque Off (STO), Safe Operating Stop (SOS), Safe Stop 1 (SS1), Safe Stop 2 (SS2) | |
| Safe direction functions | ||
| Основные | |
|---|---|
| Производитель | Axis |
- Цена: Цену уточняйте
Информация для покупателя
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Дата регистрации в Торговом реестре/Реестре бытовых услуг: 18.03.2015
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
| День | Время работы |
|---|---|
| Понедельник | 09:00-17:00 |
| Вторник | 09:00-17:00 |
| Среда | 09:00-17:00 |
| Четверг | 09:00-17:00 |
| Пятница | 09:00-17:00 |
| Суббота | Выходной |
| Воскресенье | Выходной |