Technical data | EM3702 |
---|---|
Technology | relative pressure measurement |
Number of inputs | 2 |
Measuring error | 3 % (relative to full scale value) |
Measuring range | 0…7500 hPa (7.5 bar) |
Max. overload | 10,000 hPa (10 bar) |
Resolution | 1 hPa (1 mbar) per digit |
Measuring speed | 4 ms typ. |
Current consumption E-bus | typ. 60 mA |
Current consumption power contacts | – (no power contacts) |
Bit width in the process image | 4 byte input/output per channel |
Medium | non-aggressive gases |
Operating/storage temperature | 0…+55 °C/-25…+85 °C |
Relative humidity | 95 %, no condensation |
Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
Protect. class/installation pos. | IP 20/variable |
Approvals | CE, UL |
Related products | |
---|---|
EM3701 | 1-channel differential pressure measuring terminal -100…+100 hPa (-100…+100 mbar) |
EM3712 | 2-channel relative pressure measuring terminal -1000…+1,000 hPa (-1…+1 bar) |
По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |
Или отправьте нам запрос на e-mail: zapros@filfar.by
- Цена: Цену уточняйте
ООО «ФилФар Технолоджи»
220036, г. Минск, ул. Западная, д.13, к.519
Номер в Торговом реестре/Реестре бытовых услуг: 220993, Республика Беларусь
УНП: 192123248
Регистрационный орган: Минский горисполком
Дата регистрации компании: 18.09.2013
Ссылка на свидетельство/лицензию
Режим работы:
День | Время работы |
---|---|
Понедельник | 09:00-17:00 |
Вторник | 09:00-17:00 |
Среда | 09:00-17:00 |
Четверг | 09:00-17:00 |
Пятница | 09:00-17:00 |
Суббота | Выходной |
Воскресенье | Выходной |